Workshop Manuals Factory service & repair Citroën
01 Engine02 Gearbox and clutch03 Transmission and driveshafts04 Suspension05 Steering06 Brakes07 Body - front section08 Body - rear section09 Body - side structure10 Front doors and trim11 Rear doors and trim12 Body - roof and headlining13 Body shell14 Lighting and signalling15 Wipers and washers16 Fascia and interior panels17 Front seats18 Rear seats19 Interior trim20 Electrical - general21 Starting and charging22 Locking, alarm and airbags23 Heating, air conditioning and audio
Citroën Saxo Factory Workshop Manual (1996-2004)01 · Engine
01 · Engine

Modification: ECU software (V3.3)

Make
Citroën
Model
Saxo Factory Workshop Manual
Year
1996–2004
Section
Air and fuel supply › Modification: ECU software (V3.3)
EngineModification: ECU software (V3.3)

Modification: ECU software (V3.3)

Citroën Saxo · Modifications · Ref. D6AT02P0

Applies to: Electric motor SA13 from RPO 7833

1. General

Applicable from RPO number: 7833.

Electric vehicles equipped with V3.3 software.

The V3.3 software is used to manage various parameter files.

The parameter files can be downloaded into the EEPROM memory of the ECU With the help of diagnostic tools.

The ECUs can then be configured as a function of the following components:

  • Traction battery (with increased or normal reserve)
  • Mains socket: 10, 13 or 14 A (depending on marketing country)

N.B.: EEPROM: Electrically Erasable Programmable Read Only Memory.

2. Main changes: Charge management

2.1. 12 Volt battery

If the 12 volt battery is very discharged (U battery < 3 V ± 0,5):

  • The converter is not actived
  • The permanent "CONVERTER FUNCTION" fault is not declared

ESSENTIAL: It is therefore advisable to ensure that the charge status of the 12 volt battery is correct.

2.2. Traction battery or charger

When the traction battery voltage is very discharged, the converter is no longer controlled so as not to discharge it any more.

Traction battery very discharged
-Traction batteryVoltage converter
Driving phase< 105 VoltsThe converter is not actived
Stand-by phase
Loaded< 90 Volts

The voltage converter starts to work again after the following events:

  • Starting of the on-board charger or rapid charger
  • If the traction battery voltage equals or exceeds 90 volts

2.3. Maintenance charge or initialisation charge

When programming these charges, using diagnostic tools, the following functions are performed automatically:

  • Overcharged Ah counters reset to zero
  • "Low water level" warning lamp erased

If a maintenance or initialisation charge is programmed, the "STOP" warning lamp flashes when the vehicle is driving (ignition on, circuit breaker engaged).

2.4. Normal charge - Equalisation charge

If a normal or balancing charge is interrupted and if a driving phase is performed:

  • The overcharged Ah counter is not reset to zero
  • The Ah value is taken into account during the next charge
  • The duration of the overcharging phase is extended to take account of the deficit of Ah to be overcharged

N.B.: After the vehicle has been immobilised for more than 14 days, the first charge triggered automatically is an equalising charge.

2.5. Driving management

The motor on warning buzzer is replaced by a safety device which causes the circuit-breaker to open when the driver’s door is opened.

N.B.: The circuit breaker is re-engaged by operating the contact.

The stop lamps no longer illuminate automatically when decelerating.

When the energy gauge indicates a value < 20 %, the "charging request" and "temporary limitation" warning lamps illuminate simultaneously.

2.6. New diagnostic functions

N.B.: These new functions appear with CD-ROM number 13 updates.

2.7. Read fault

The appearance of the permanent "traction battery charger thermal safety" fault causes charging to stop.

N.B.: The "traction battery charger thermal safety" is linked to a cooling problem of the electronic unit.

2.8. Traction battery maintenance

functionsRemarks
Charge condition memorisedThis new menu gives the information relating to traction battery charging
Charge programmedIndication of the programmed charge using the diagnostic tools
Last rapid charge statusDuring the last rapid charge, if a fault number greater than "128" appears, the tester displays incorrect, otherwise the tester displays correct
StatusThe tester displays the code of the fault recorded during the last rapid charge
Max voltage/min voltageMin and max voltage values reached during the last rapid charge
Cancelling the programmed chargeThis menu is used to cancel the charge programmed by the diagnostic tools
Battery recordThis new menu presents information relating to the history of the traction battery
Lighting of the water warning lightOvercharged Ah counter during overcharge phases of normal or equalisation charges
If the counter displays a value greater than 950 Ah, perform the following operations:
Maintenance charge
Topping up of the battery electrolyte level
Erasure of the water warning lamp
Returning the vehicle to the owner
Warning lamp thresholdValue of the overcharged Ah counter to illuminate the "low water level" warning lamp: 1110 Ah
Cumulatives (overcharge, discharge, duration) and "T °C" limitThese values may be requested by the Electric Vehicles technical liaison team
This information is required to complete the "traction battery" analysis form
Clearing of totalsThis possibility is used to reset all the counters of the battery history menu to zero

CAUTION: Only use the "erase cumulatives" command when replacing all the traction battery compartments.

2.9. Measure parameters

Convertor/load measurement.

Disappearance of the following parameters in the "charge/converter measurement" menu:

  • Charge programmed
  • Rapid charge
  • Battery type pin

N.B.: The "programmed charge" and "rapid charge" information are in the "memorised charge status" menu.

2.10. Actuators test

The "automatic test" function is used to perform the actuator tests one after the other:

  • Without returning to the actuator selection menu
  • Without switching the ignition off or on

2.11. Configuration

functionsRemarks
Choice of battery typeTraction battery (with increased or normal reserve)
Choice of mains socket type10, 13 or 14 A (depending on marketing country)
Taking the parameters into accountIt is no longer necessary to remove the breaker element from the traction battery for the parameters to be taken into account
ECU selftestThe self-test procedure enables the various ECU memories to be tested following the appearance of a fault (see the relevant operation)

3. Interchangeability

Only computers with V3.3 software are supplied by the Replacement Parts Division.

It is necessary to carry out the configuration procedure when a new electronic unit or a new control unit is fitted.

If it is not possible to memorise the Ah (diagnostic line not working), perform the following operations:

  • Initialisation charge
  • Top up the traction battery water level
  • Deletion of water needed counter
Replacing an ECU or an electronic unit
RPO numberBefore 7724Between 7724 and 7833more than 7833
ECU softwareV3.1C versionV3.1C versionV3.3 version
Number of parameter files to be downloaded022/023/024025/026/027025/026/027
Traction batteryNormal capacityIncreased capacity
Identification (diagnostic tools)"Ni/Cd""Ni/Cd R""Ni/Cd R"
Mains socket10, 13 or 14 A

Ni/Cd R = Nickel Cadmium battery with increased reserve.

4. Identification

New information appears on the identification screen of the following diagnostic tools:

  • ELIT unit
  • PROXIA station
  • LEXIA station

4.1. Description

functionsRemarks
High voltage software versionHigh voltage microcontroller software version: Display "03.3C"
Low voltage software versionLow voltage microcontroller software version: Display "03.3C"
Parameter versionName of the EEPROM parameter file version
Type of mains plug used for the on-board charge10, 13 or 14 A
Mains socket
Battery componentsNumber of components in the traction battery: Display "100"
Battery type parameterIf the traction battery has increased reserve: Display "Ni/Cd R"
-If the traction battery has normal reserve: Display "Ni/Cd"

4.2. Parameter version

Parameter file numberTraction battery typeMains socket
022Normal capacity14 A
02313 A
02410 A
025Increased capacity14 A
02613 A
02710 A

If the version of the parameter file is lower than the one contained in the diagnostic tools, the words "perform downloading" are displayed.

If the version of the parameter file is higher than "128", the words "incorrect parameters" are displayed.

If the ECU is new, it must be configured (see the relevant operation).

If it is an EEPROM memory fault (loss of information), perform a self-test of the ECU memories in this case.

Parts & tools for this job For 1996 Citroën Saxo