Modification: ECU software (V3.3)
- Make
- Citroën
- Model
- Saxo Factory Workshop Manual
- Year
- 1996–2004
- Section
- Air and fuel supply › Modification: ECU software (V3.3)
Modification: ECU software (V3.3)
1. General
Applicable from RPO number: 7833.
Electric vehicles equipped with V3.3 software.
The V3.3 software is used to manage various parameter files.
The parameter files can be downloaded into the EEPROM memory of the ECU With the help of diagnostic tools.
The ECUs can then be configured as a function of the following components:
- Traction battery (with increased or normal reserve)
- Mains socket: 10, 13 or 14 A (depending on marketing country)
N.B.: EEPROM: Electrically Erasable Programmable Read Only Memory.
2. Main changes: Charge management
2.1. 12 Volt battery
If the 12 volt battery is very discharged (U battery < 3 V ± 0,5):
- The converter is not actived
- The permanent "CONVERTER FUNCTION" fault is not declared
ESSENTIAL: It is therefore advisable to ensure that the charge status of the 12 volt battery is correct.
2.2. Traction battery or charger
When the traction battery voltage is very discharged, the converter is no longer controlled so as not to discharge it any more.
| Traction battery very discharged | ||
|---|---|---|
| - | Traction battery | Voltage converter |
| Driving phase | < 105 Volts | The converter is not actived |
| Stand-by phase | ||
| Loaded | < 90 Volts | |
The voltage converter starts to work again after the following events:
- Starting of the on-board charger or rapid charger
- If the traction battery voltage equals or exceeds 90 volts
2.3. Maintenance charge or initialisation charge
When programming these charges, using diagnostic tools, the following functions are performed automatically:
- Overcharged Ah counters reset to zero
- "Low water level" warning lamp erased
If a maintenance or initialisation charge is programmed, the "STOP" warning lamp flashes when the vehicle is driving (ignition on, circuit breaker engaged).
2.4. Normal charge - Equalisation charge
If a normal or balancing charge is interrupted and if a driving phase is performed:
- The overcharged Ah counter is not reset to zero
- The Ah value is taken into account during the next charge
- The duration of the overcharging phase is extended to take account of the deficit of Ah to be overcharged
N.B.: After the vehicle has been immobilised for more than 14 days, the first charge triggered automatically is an equalising charge.
2.5. Driving management
The motor on warning buzzer is replaced by a safety device which causes the circuit-breaker to open when the driver’s door is opened.
N.B.: The circuit breaker is re-engaged by operating the contact.
The stop lamps no longer illuminate automatically when decelerating.
When the energy gauge indicates a value < 20 %, the "charging request" and "temporary limitation" warning lamps illuminate simultaneously.
2.6. New diagnostic functions
N.B.: These new functions appear with CD-ROM number 13 updates.
2.7. Read fault
The appearance of the permanent "traction battery charger thermal safety" fault causes charging to stop.
N.B.: The "traction battery charger thermal safety" is linked to a cooling problem of the electronic unit.
2.8. Traction battery maintenance
| functions | Remarks |
|---|---|
| Charge condition memorised | This new menu gives the information relating to traction battery charging |
| Charge programmed | Indication of the programmed charge using the diagnostic tools |
| Last rapid charge status | During the last rapid charge, if a fault number greater than "128" appears, the tester displays incorrect, otherwise the tester displays correct |
| Status | The tester displays the code of the fault recorded during the last rapid charge |
| Max voltage/min voltage | Min and max voltage values reached during the last rapid charge |
| Cancelling the programmed charge | This menu is used to cancel the charge programmed by the diagnostic tools |
| Battery record | This new menu presents information relating to the history of the traction battery |
| Lighting of the water warning light | Overcharged Ah counter during overcharge phases of normal or equalisation charges |
| If the counter displays a value greater than 950 Ah, perform the following operations: | |
| Maintenance charge | |
| Topping up of the battery electrolyte level | |
| Erasure of the water warning lamp | |
| Returning the vehicle to the owner | |
| Warning lamp threshold | Value of the overcharged Ah counter to illuminate the "low water level" warning lamp: 1110 Ah |
| Cumulatives (overcharge, discharge, duration) and "T °C" limit | These values may be requested by the Electric Vehicles technical liaison team |
| This information is required to complete the "traction battery" analysis form | |
| Clearing of totals | This possibility is used to reset all the counters of the battery history menu to zero |
CAUTION: Only use the "erase cumulatives" command when replacing all the traction battery compartments.
2.9. Measure parameters
Convertor/load measurement.
Disappearance of the following parameters in the "charge/converter measurement" menu:
- Charge programmed
- Rapid charge
- Battery type pin
N.B.: The "programmed charge" and "rapid charge" information are in the "memorised charge status" menu.
2.10. Actuators test
The "automatic test" function is used to perform the actuator tests one after the other:
- Without returning to the actuator selection menu
- Without switching the ignition off or on
2.11. Configuration
| functions | Remarks |
|---|---|
| Choice of battery type | Traction battery (with increased or normal reserve) |
| Choice of mains socket type | 10, 13 or 14 A (depending on marketing country) |
| Taking the parameters into account | It is no longer necessary to remove the breaker element from the traction battery for the parameters to be taken into account |
| ECU selftest | The self-test procedure enables the various ECU memories to be tested following the appearance of a fault (see the relevant operation) |
3. Interchangeability
Only computers with V3.3 software are supplied by the Replacement Parts Division.
It is necessary to carry out the configuration procedure when a new electronic unit or a new control unit is fitted.
If it is not possible to memorise the Ah (diagnostic line not working), perform the following operations:
- Initialisation charge
- Top up the traction battery water level
- Deletion of water needed counter
| Replacing an ECU or an electronic unit | |||
|---|---|---|---|
| RPO number | Before 7724 | Between 7724 and 7833 | more than 7833 |
| ECU software | V3.1C version | V3.1C version | V3.3 version |
| Number of parameter files to be downloaded | 022/023/024 | 025/026/027 | 025/026/027 |
| Traction battery | Normal capacity | Increased capacity | |
| Identification (diagnostic tools) | "Ni/Cd" | "Ni/Cd R" | "Ni/Cd R" |
| Mains socket | 10, 13 or 14 A | ||
Ni/Cd R = Nickel Cadmium battery with increased reserve.
4. Identification
New information appears on the identification screen of the following diagnostic tools:
- ELIT unit
- PROXIA station
- LEXIA station
4.1. Description
| functions | Remarks |
|---|---|
| High voltage software version | High voltage microcontroller software version: Display "03.3C" |
| Low voltage software version | Low voltage microcontroller software version: Display "03.3C" |
| Parameter version | Name of the EEPROM parameter file version |
| Type of mains plug used for the on-board charge | 10, 13 or 14 A |
| Mains socket | |
| Battery components | Number of components in the traction battery: Display "100" |
| Battery type parameter | If the traction battery has increased reserve: Display "Ni/Cd R" |
| - | If the traction battery has normal reserve: Display "Ni/Cd" |
4.2. Parameter version
| Parameter file number | Traction battery type | Mains socket |
|---|---|---|
| 022 | Normal capacity | 14 A |
| 023 | 13 A | |
| 024 | 10 A | |
| 025 | Increased capacity | 14 A |
| 026 | 13 A | |
| 027 | 10 A |
If the version of the parameter file is lower than the one contained in the diagnostic tools, the words "perform downloading" are displayed.
If the version of the parameter file is higher than "128", the words "incorrect parameters" are displayed.
If the ECU is new, it must be configured (see the relevant operation).
If it is an EEPROM memory fault (loss of information), perform a self-test of the ECU memories in this case.
Parts & tools for this job For 1996 Citroën Saxo
- PARTEngine gasket setSearch: Citroën Saxo 1996 engine gasket set
- TOOLTorque wrenchSearch: 3/8 inch torque wrench
- TOOLFeeler gauge setSearch: feeler gauge set
As an Amazon Associate we earn from qualifying purchases.