Workshop Manuals Factory service & repair Citroën
01 Engine02 Gearbox and clutch03 Transmission and driveshafts04 Suspension05 Steering06 Brakes07 Body - front section08 Body - rear section09 Body - side structure10 Front doors and trim11 Rear doors and trim12 Body - roof and headlining13 Body shell14 Lighting and signalling15 Wipers and washers16 Fascia and interior panels17 Front seats18 Rear seats19 Electrical - general20 Starting and charging21 Wiring harnesses22 Locking, alarm and airbags23 Heating, air conditioning and audio
Citroën Xantia Factory Workshop Manual (1993-1998)04 · Suspension
04 · Steering & suspension

Check: Hydraulic components

Make
Citroën
Model
Xantia Factory Workshop Manual
Year
1993–1998
Section
Suspension › Check: Hydraulic components
SuspensionCheck: Hydraulic components

Check: Hydraulic components

Citroën Xantia · Checks · Ref. B4BD01P0

Applies to: all versions

1. Recommended tools

Figure b4bp00kc

[1] hydraulic test bench 4034-T.

Pressure gauge complete 3657-T.

Suspension blocks for vehicles in the showroom 8001-TA and 8001-TB.

2. Preparation

Place the vehicle on a lift.

In the event of the security valve being checked, set the vehicle to the "NORMAL DRIVING POSITION".

Figure b4bp00lc

Ensure that the filters of the hydraulic reservoir are clean.

Pressurize the hydraulic circuits, in the "NORMAL DRIVING POSITION".

Uncouple the return pipes to the reservoir successively in order to check them for leaks.

When the system is new, there is almost no fluid running.

When testing, a seepage is allowed. A fluid overflow requires replacing the part concerned.

If a return pipe leaks, check the outlet of the components concerned by this set of pipes.

Figure b4bp00md
PipesPartmanual steeringpower assisted steeringHydractive suspensionABS/ASR
1high pressure pumpXXXX
Suction line
2Pressure regulatorX---
ReturnFlow distributor-XX-
-Front solenoid valve--X-
3Steering assembly ram-X--
-Front/rear height corrector10101010
4Front suspension cylinder11111111
-Rear suspension cylinder10101010
LeaksSecurity valve10101010
-Pressure regulator-11--
-Rear solenoid valve--10-
5Front height corector8888
ReturnRear height corrector9999
6Brake control valve12/1312/1312/1312/13
Returnhydraulic valve block---14
7Steering valve-X--
Return-----

N.B.: When the engine is running, return pipes 2 and 7 have a continuous output.

3. Checking the pressure regulator and the main accumulator

Figure b4bp00nc

Slacken the release screw.

Uncouple the main feed pipe (16) from the pressure regulator.

Figure b4bp00pc

Couple up a 0 to 250 bars pressure gauge with the pressure regulator, via a pipe.

3.1. Checking the cut-out pressure

Tighten the release screw.

Start the engine.

The pressure gauge reading should indicate the cut-out pressure: 170 ± 5 bars.

3.2. Checking the cut-in pressure

Once the cut-out has taken place, slacken the release screw a little.

The pressure drops gently to reach the 145 ± 5 bars cut-in value, then rises.

3.3. Checking the main accumulator

When the cut-out or the cut-in pressure has been reached, stop the engine.

Slightly loosen the release screw, To create a slow and regular drop in pressure.

Once a certain reading is obtained, the pressure drops suddenly. This reading is the inflation pressure of the main accumulator: 62 (+2, -32) bars.

3.4. Checking the pressure regulator for leaks

Tighten the release screw.

Start the engine.

When the cut-out pressure is reached, let the pressure settle then switch off the engine.

Watch the pressure gauge. Note the drop in pressure for a period of 3 minutes. If the drop exceeds 20 bars, the pressure regulator is defective.

4. Checking the security valve

Figure b4bp00qc

Set the vehicle to the "NORMAL DRIVING POSITION".

N.B.: The suspension blocks for a vehicle in the showroom 8001-TA and 8001-TB can be used.

Slacken the release screw.

Couple general supply pipe (16) with hydraulic test bench [18] via a double union.

4.1. Checking the security valve setting

Set the height control to the "HIGH" position.

Turn off the hydraulic test bench tap.

Operate the hydraulic test bench pump.

When a certain reading has been reached, the pressure settles and then tends to drop again.

This reading, which should be between 80 and 100 bars, shows that the slide valve starts moving.

4.2. Checking the fault finding device

Set the height control to the "LOW" position.

Switch on the ignition.

Operate the hydraulic test bench pump.

The hydraulic fluid warning lamp located on the instrument panel will go out when the pressure value is greater than the setting pressure of the security valve (from 80 to 100 bars).

N.B.: The fault finding device warning lamp is coupled up with the LHM oil level indicator and the engine oil pressure switch.

4.3. Checking the fault finding device: 1st possibility

Disconnect the engine oil pressure switch located, according to the model:

  • Above the oil filter
  • Beside the oil dipstick

4.4. Checking the fault finding device: 2nd possibility

Figure b4bp00rc

Unclip the 3-way grey connector (19) from under the L.H. headlamp.

Connect an indicator bulb between the terminal 2 and the battery +.

N.B.: The indicator bulb operation is similar to that of the warning lamp located on the instrument panel.

5. Checking the pressure of the flow regulator

Figure b4bp00sc

Slightly loosen the release screw.

Uncouple from flow distributor (21), steering feed pipe (9), 4,5 mm in Ø.

Couple up a 0 to 250 bars pressure gauge with flow distributor (21) by means of a 3-way union.

Couple up the 3-way union (20) with the flow distributor via a pipe.

Connect steering feed pipe (23) to the 3-way union.

Tighten the release screw.

Start the engine.

Turn the steering. The pressure increases according to the resistance coming in from the road wheels.

With the steering turned to full lock, the pressure obtained should be between 150 and 165 bars.

6. Checking an accumulator or a hydropneumatic sphere

Figure b4bp00tc

Couple up the accumulator or the hydropneumatic sphere with the hydraulic test bench [1].

Connect the pump to the pressure gauge graduated 0 to 100 bars.

Turn off the hydraulic test bench tap.

Operate the hydraulic test bench pump.

The pressure will increase, then settle to the hydropneumatic sphere inflation pressure value.

N.B.: The initial pressure setting is stamped on the plug.

Turn on the hydraulic bench tap to release the pressure.

7. Checking the pressure regulator on the hydraulic test bench

Figure b4bp00uc

Fit a plug (24), together with its seal, to the pressure regulator, where the main accumulator was removed.

Block up with a plug (26) the orifice of the hydraulic test bench [1] pump.

Connect the orifice of the hydraulic test bench pump to the inlet hole (27), (6,35 mm Ø) of the pressure regulator.

Connect the outlet orifice (25) (4,5 mm in Ø) of the pressure regulator to the test bench pressure gauge graduated 0 to 250 bars.

7.1. Checking the cut-out pressure

Actuate the pump until the cut-out pressure is obtained.

At that moment, the hydraulic fluid runs out from reservoir return hole (28) and the pump lever can be operated easily.

Read the pressure value at the very moment when the cut-out pressure is obtained (the pressure gauge needle will drop immediately after).

The pressure reading should be 170 ± 5 bars.

If the pressure regulator is defective, the needle will not settle; the hydraulic fluid will flow through orifice (28) and the pump lever will still be stiff in operation.

7.2. Checking the cut-in pressure

Loosen release screw (15) to slowly let the pressure drop, whilst pumping at the same time.

The pump lever can be operated easily and hydraulic fluid starts flowing continuously via orifice.

Read the pressure value indicated on the pressure gauge as soon as the fluid stops from escaping.

At this point, the pump lever becomes stiff again.

The pressure reading should be 145 ± 5 bars.

Parts & tools for this job For 1993 Citroën Xantia

As an Amazon Associate we earn from qualifying purchases.