Check: Hydraulic components
1. Recommended tools
[1] hydraulic test bench 4034-T.
Pressure gauge complete 3657-T.
Suspension blocks for vehicles in the showroom 8001-TA and 8001-TB.
2. Preparation
Place the vehicle on a lift.
In the event of the security valve being checked, set the vehicle to the "NORMAL DRIVING POSITION".
Ensure that the filters of the hydraulic reservoir are clean.
Pressurize the hydraulic circuits, in the "NORMAL DRIVING POSITION".
Uncouple the return pipes to the reservoir successively in order to check them for leaks.
When the system is new, there is almost no fluid running.
When testing, a seepage is allowed. A fluid overflow requires replacing the part concerned.
If a return pipe leaks, check the outlet of the components concerned by this set of pipes.
| Pipes | Part | manual steering | power assisted steering | Hydractive suspension | ABS/ASR |
|---|---|---|---|---|---|
| 1 | high pressure pump | X | X | X | X |
| Suction line | |||||
| 2 | Pressure regulator | X | - | - | - |
| Return | Flow distributor | - | X | X | - |
| - | Front solenoid valve | - | - | X | - |
| 3 | Steering assembly ram | - | X | - | - |
| - | Front/rear height corrector | 10 | 10 | 10 | 10 |
| 4 | Front suspension cylinder | 11 | 11 | 11 | 11 |
| - | Rear suspension cylinder | 10 | 10 | 10 | 10 |
| Leaks | Security valve | 10 | 10 | 10 | 10 |
| - | Pressure regulator | - | 11 | - | - |
| - | Rear solenoid valve | - | - | 10 | - |
| 5 | Front height corector | 8 | 8 | 8 | 8 |
| Return | Rear height corrector | 9 | 9 | 9 | 9 |
| 6 | Brake control valve | 12/13 | 12/13 | 12/13 | 12/13 |
| Return | hydraulic valve block | - | - | - | 14 |
| 7 | Steering valve | - | X | - | - |
| Return | - | - | - | - | - |
N.B.: When the engine is running, return pipes 2 and 7 have a continuous output.
3. Checking the pressure regulator and the main accumulator
Slacken the release screw.
Uncouple the main feed pipe (16) from the pressure regulator.
Couple up a 0 to 250 bars pressure gauge with the pressure regulator, via a pipe.
3.1. Checking the cut-out pressure
Tighten the release screw.
Start the engine.
The pressure gauge reading should indicate the cut-out pressure: 170 ± 5 bars.
3.2. Checking the cut-in pressure
Once the cut-out has taken place, slacken the release screw a little.
The pressure drops gently to reach the 145 ± 5 bars cut-in value, then rises.
3.3. Checking the main accumulator
When the cut-out or the cut-in pressure has been reached, stop the engine.
Slightly loosen the release screw, To create a slow and regular drop in pressure.
Once a certain reading is obtained, the pressure drops suddenly. This reading is the inflation pressure of the main accumulator: 62 (+2, -32) bars.
3.4. Checking the pressure regulator for leaks
Tighten the release screw.
Start the engine.
When the cut-out pressure is reached, let the pressure settle then switch off the engine.
Watch the pressure gauge. Note the drop in pressure for a period of 3 minutes. If the drop exceeds 20 bars, the pressure regulator is defective.
4. Checking the security valve
Set the vehicle to the "NORMAL DRIVING POSITION".
N.B.: The suspension blocks for a vehicle in the showroom 8001-TA and 8001-TB can be used.
Slacken the release screw.
Couple general supply pipe (16) with hydraulic test bench [18] via a double union.
4.1. Checking the security valve setting
Set the height control to the "HIGH" position.
Turn off the hydraulic test bench tap.
Operate the hydraulic test bench pump.
When a certain reading has been reached, the pressure settles and then tends to drop again.
This reading, which should be between 80 and 100 bars, shows that the slide valve starts moving.
4.2. Checking the fault finding device
Set the height control to the "LOW" position.
Switch on the ignition.
Operate the hydraulic test bench pump.
The hydraulic fluid warning lamp located on the instrument panel will go out when the pressure value is greater than the setting pressure of the security valve (from 80 to 100 bars).
N.B.: The fault finding device warning lamp is coupled up with the LHM oil level indicator and the engine oil pressure switch.
4.3. Checking the fault finding device: 1st possibility
Disconnect the engine oil pressure switch located, according to the model:
- Above the oil filter
- Beside the oil dipstick
4.4. Checking the fault finding device: 2nd possibility
Unclip the 3-way grey connector (19) from under the L.H. headlamp.
Connect an indicator bulb between the terminal 2 and the battery +.
N.B.: The indicator bulb operation is similar to that of the warning lamp located on the instrument panel.
5. Checking the pressure of the flow regulator
Slightly loosen the release screw.
Uncouple from flow distributor (21), steering feed pipe (9), 4,5 mm in Ø.
Couple up a 0 to 250 bars pressure gauge with flow distributor (21) by means of a 3-way union.
Couple up the 3-way union (20) with the flow distributor via a pipe.
Connect steering feed pipe (23) to the 3-way union.
Tighten the release screw.
Start the engine.
Turn the steering. The pressure increases according to the resistance coming in from the road wheels.
With the steering turned to full lock, the pressure obtained should be between 150 and 165 bars.
6. Checking an accumulator or a hydropneumatic sphere
Couple up the accumulator or the hydropneumatic sphere with the hydraulic test bench [1].
Connect the pump to the pressure gauge graduated 0 to 100 bars.
Turn off the hydraulic test bench tap.
Operate the hydraulic test bench pump.
The pressure will increase, then settle to the hydropneumatic sphere inflation pressure value.
N.B.: The initial pressure setting is stamped on the plug.
Turn on the hydraulic bench tap to release the pressure.
7. Checking the pressure regulator on the hydraulic test bench
Fit a plug (24), together with its seal, to the pressure regulator, where the main accumulator was removed.
Block up with a plug (26) the orifice of the hydraulic test bench [1] pump.
Connect the orifice of the hydraulic test bench pump to the inlet hole (27), (6,35 mm Ø) of the pressure regulator.
Connect the outlet orifice (25) (4,5 mm in Ø) of the pressure regulator to the test bench pressure gauge graduated 0 to 250 bars.
7.1. Checking the cut-out pressure
Actuate the pump until the cut-out pressure is obtained.
At that moment, the hydraulic fluid runs out from reservoir return hole (28) and the pump lever can be operated easily.
Read the pressure value at the very moment when the cut-out pressure is obtained (the pressure gauge needle will drop immediately after).
The pressure reading should be 170 ± 5 bars.
If the pressure regulator is defective, the needle will not settle; the hydraulic fluid will flow through orifice (28) and the pump lever will still be stiff in operation.
7.2. Checking the cut-in pressure
Loosen release screw (15) to slowly let the pressure drop, whilst pumping at the same time.
The pump lever can be operated easily and hydraulic fluid starts flowing continuously via orifice.
Read the pressure value indicated on the pressure gauge as soon as the fluid stops from escaping.
At this point, the pump lever becomes stiff again.
The pressure reading should be 145 ± 5 bars.