Climate control not cooling
- Make
- Fiat
- Model
- Doblò Factory Service Manual
- Year
- 2000–2010
- Section
- Climate control › Climate control not cooling
Fault diagnosisClimate control not cooling
CLIMATE CONTROL NOT COOLING
The control button operates the passenger compartment air fan normally, but this air is at the outside temperature and has not been cooled.
| Results of the tests | ||||
| 1 | BELT CONDITION CHECK | All OK | Problems met | Operation |
|---|---|---|---|---|
| 1.2 8v | Check the condition of the compressor drive belt and make sure the tension is correct. | Continue to Step 2 | Belt defective | Replace the belt Op. 1092D10 |
| Tension incorrect | Restore correct tension Op. 1092D14 | |||
| 1.9 DIESEL | Check the condition of the compressor drive belt and make sure the tension is correct. | Continue to Step 2 | Belt defective | Replace the belt Op. 1092G10 |
| 2 | CHECK ELECTRICAL CIRCUIT | All OK | Problems met | Operation |
Check, in order:
| Continue to Step 3 | Component defective | Replace fuse (and search for the cause of the problem) | |
| Connections not correct | Restore connections | |||
| 3 | CHECK WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
| Connect the diagnostic equipment (Examiner or other instruments) to the diagnostic socket and carry out active diagnosis of the compressor relay. | Continue to Step 4 | Relay faulty | Replace the relay | |
| 4 | CLIMATE CONTROL COMPONENTS CHECK | All OK | Problems met | Operation |
Check, in order:
| Continue to Step 5 | Compressor control faulty | Replace the compressor control Op. 5040A22 | |
| 4 stage pressure switch faulty | Replace the pressure switch Op. 5040B14 | |||
| Electronic thermostat faulty | Replace the electronic thermostat Op. 5040B22 | |||
| 5 | CHECK COMPRESSOR ELECTRO-MAGNET COUPLING | All OK | Problems met | Operation |
| Check the operation of the compressor electro-magnet coupling. In particular, check the resistance, coil, supply and earth. | Continue to Step 6 | Electro-magnetic coupling malfunction | Replace the compressor Op. 5040A20 | |
| 6 | SYSTEM PRESSURE CHECK | All OK | Problems met | Operation |
| Connect the climate control system to the repressurizing system and check the system pressure See Test 5040B | Continue to Step 7 | The pressures do not alter much when the compressor is switched on | Replace the compressor Op. 5040A20 | |
| The high and low pressures vary, but do not reach the correct values. | Repressurize the system Op. 5040A10 | |||
| Evaporator dirty | Replace the evaporator Op. 5040C10 | |||
| 7 | CHECK ON CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | Fault persists | Search for the fault starting from another symptom' | ||
Parts & tools for this job For 2000 Fiat Doblò
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Fiat Doblò 2000 cabin filter
Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.