Climate control too cold
- Make
- Fiat
- Model
- Doblò Factory Service Manual
- Year
- 2000–2010
- Section
- Climate control › Climate control too cold
Fault diagnosisClimate control too cold
CLIMATE CONTROL TOO COLD
The control button operates the passenger compartment air fan normally, but the temperature of the air is not correct.
| Results of the tests | ||||
| 1 | AIR TEMPERATURE CHECK | All OK | Problems met | Operation |
|---|---|---|---|---|
| Check the temperature of the air at the vents See Test 5040A | Continue to Step 9 | Ambient temperature at the vents | Continue to Step 2 | |
| Temperature at the vents higher than desired | Continue to Step 3 | |||
| 2 | SYSTEM PRESSURE CHECK | All OK | Problems met | Operation |
| Connect the climate control system to the repressurizing equipment and check the system pressure See Test 5040B | Continue to Step 9 | High and low pressure values below correct figures. | Continue to Step 6 | |
| 3 | SYSTEM PRESSURE CHECK | All OK | Problems met | Operation |
| Connect the climate control system to the repressurizing equipment and check the system pressure See Test 5040B | Continue to Step 9 | High and low pressure values below correct figures. | Repressurize the system Op. 5040A10 | |
| High and low pressure values above correct figures. | Continue to Step 4 | |||
| Low pressure value correct, but high pressure value above correct figure (rapid compressor cycle as engine rpm increases) | Continue to Step 5 | |||
| Low pressure value high and high pressure value below correct figure | Replace the compressor Op. 5040A20 | |||
| High and low pressure vaules do not alter when the air conditioning is activated. | Replace the compressor Op. 5040A20 | |||
| 4 | CONDENSER FAN CHECK | All OK | Problems met | Operation |
| Check that the fan cools the condenser correctly. | Continue to Step 5 | Electric fan defective | Replace the fan Op. 5040C30 | |
| 5 | CIRCUIT LOADING CHECK | All OK | Problems met | Operation |
| Check that the system loading is not excessive. | Continue to Step 7 | System loading excessive. | Restore the correct loading Op. 5040A10 | |
| 6 | COOLANT CIRCUIT OBSTRUCTION CHECK | All OK | Problems met | Operation |
| Check that the pipes and the filter are not obstructed. | Continue to Step 8 | Pipe obstructed | Replace the pipe | |
| Filter obstructed | Replace the filter Op. 5040A44 | |||
| 7 | CONDENSER CHECK | All OK | Problems met | Operation |
| Check that the condenser is not blocked. | Continue to Step 8 | Condenser blocked | Replace the condenser | |
| 8 | EXPANSION VALVE CHECK | All OK | Problems met | Operation |
| Check the operation of the expansion valve. | Continue to Step 9 | Expansion valve defective | Replace the expansion valve Op. 5040B30 | |
| 9 | CHECK ON CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | Fault persists | Search for the fault starting from another symptom' | ||
Parts & tools for this job For 2000 Fiat Doblò
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Fiat Doblò 2000 cabin filter
Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.