Workshop Manuals Factory service & repair Fiat
01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Special tools
Fiat Doblò Factory Service Manual (2000-2010)22 · Fault diagnosis
22 · Diagnostics

CO EMISSIONS LOW, NOx EMISSIONS HIGH

Make
Fiat
Model
Doblò Factory Service Manual
Year
2000–2010
Section
Emissions › CO EMISSIONS LOW, NOx EMISSIONS HIGH
Fault diagnosisCO EMISSIONS LOW, NOx EMISSIONS HIGH

CO EMISSIONS LOW, NOx EMISSIONS HIGH

The CO percentage measured is very low, with a corresponding NOx percentage higher than the recommended figure.

Results of the tests
1CHECK WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation

Connect diagnostic equipment (Examiner or other instruments) to the diagnostic socket.

Check that there are no faults in the engine management control unit

Continue to Step 2'Supply system' error detectedSee table Z50 MIXTURE STRENGTH ERROR
'Misfire' error detectedSee table Z53 MISFIRE ERROR
'Catalytic converter' error detectedSee table Z55 CATALYZER ERROR
'Upstream lambda sensor' error detectedSee table Z56 UPSTREAM LAMBDA SENSOR SIGNAL ERROR
'Downstream lambda sensor' error detectedSee table Z58 DOWNSTREAM LAMBDA SENSOR SIGNAL ERROR
Another error detected in the control unitContinue following the instructions for the diagnostic equipment
Lack of dialogue with the control unitRestore the connection between the engine management control unit and the diagnostic connector See E5030 PETROL ENGINE ELECTRONIC MANAGEMENT
2ACTIVE DIAGNOSIS WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation
Using the diagnostic equipment (Examiner or other instruments) carry out active diagnosis of the injectorsContinue to Step 3Connections faultyRestore the connection of the injectors and the solenoid with the control unit See E5030 PETROL ENGINE ELECTRONIC MANAGEMENT
Faulty injectorReplace injector Op. 1056B70
3CHECKING LAMBDA SENSORAll OKProblems metOperation
Check that the Lambda sensor is working properlyContinue to Step 4Upper lambda sensor defectiveReplace the upper Lambda sensor Op. 1080B94
Lower lambda sensor defectiveReplace the lower Lambda sensor Op. 1080B95
4CHECKING AIR CIRCUITAll OKProblems metOperation
Check the condition of the air supply circuitContinue to Step 5Circuit component damagedReplace the component involved
5CHECKING BLOW-BY CIRCUITAll OKProblems metOperation
Check the condition of the blow-by gas intake circuit, in particular, check that there are no obstructions in the separator or the pipesContinue to Step 6Circuit faultyRestore the operation of the system
Fault in the separatorReplace the separator
6CHECKING FUEL PRESSUREAll OKProblems metOperation
Check the fuel supply pressure Op. 0510C10Continue to Step 7Pressure not correctReplace the fuel pump Op. 1040A70
7CHECKING CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentFault persistsSearch for the fault starting from another symptom'

Parts & tools for this job For 2000 Fiat Doblò

Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.