Climate control not cooling
- Make
- Fiat
- Model
- Multipla Factory Service Manual
- Year
- 1998–2010
- Section
- Climate control › Climate control not cooling
CLIMATE CONTROL NOT COOLING
The control unit operates the fan which sends air into the passenger compartment normally with the pre-set flows, but this air is at the outside temperature and is not cooled.
| Results of the tests | ||||
| 0 | PRELIMINARY CHECKS | All OK | Problems met | Operation |
|---|---|---|---|---|
1.6 16v Air Conditioner | Check the condition of the compressor drive belt | Continue to Step 1 | Tension incorrect | Replace the belt Op. 1092D10 |
1.9 JTD 8V Air Conditioner | Continue to Step 1 | |||
| 1 | COMPRESSOR ENGAGEMENT CHECK | All OK | Problems met | Operation |
| Using the diagnostic equipment (Examiner or other instruments) carry out the active diagnosis of the operation of the compressore relay (in the engine management control unit ambient) | Continue to Step 2 | Compressore relay faulty | Check and, if necessary, replace the compressor engagement relay | |
| Component defective | Replace the component involved (if a fuse is involved, search for the cause of the problem) | |||
| Connections not correct | Restore the connections between engine management control unit, relay and compressor coupling See E6021 COMPRESSOR ENGAGEMENT | |||
| 2 | CHECK COMPRESSOR ACTIVATION ELECTRICAL CIRCUIT | All OK | Problems met | Operation |
Check, in order:
| Continue to Step 3 | Connections not correct | Restore the connections | |
| Pressure switch defective | Replace the pressure switch Op. 5040B14 | |||
| Antifrost thermostat defective | Replace antifrost thermostat Op. 5040B64 | |||
| Control defective | Change control unit Op. 7065C10 | |||
| 3 | CHECK COMPRESSOR ELECTRO-MAGNET COUPLING | All OK | Problems met | Operation |
| Check the operation of the compressor electro-magnet coupling and, in particular, that it is correctly connected to earth | Continue to Step 4 | Compressor electro-magnet coupling malfunction | Replace the compressor Op. 5040A20complete with electro-magnet coupling | |
| 4 | SYSTEM PRESSURE CHECK | All OK | Problems met | Operation |
| Check the system pressure: See Test 5040B Check on operation of air conditioning system (pressures) | Continue to Step 5 | High pressure does not increase or low pressure decreases too much: leaks in the circuit | Locate these leaks Op. 5040A14, then restore the condition of the circuit | |
| High pressure continues to increase: and the compressor cooling fan does not operate. | See table D31 | |||
| 5 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation |
Check that there are no reasons why the climate control control unit or the engine control unit do not enable the engagement of the cooling circuit. For more details see DESCRIPTION AND OPERATION: 5040 AIR CONDITIONING CASING AND COMPONENTS | End of diagnosis | Fault persists | Search for the fault starting from another symptom' | |