01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Special tools
Fiat Multipla Factory Service Manual (1998-2010)22 · Fault diagnosis
22 · Diagnostics

Climate control not cooling

Make
Fiat
Model
Multipla Factory Service Manual
Year
1998–2010
Section
Climate control › Climate control not cooling
Fault diagnosisClimate control not cooling

CLIMATE CONTROL NOT COOLING

The control unit operates the fan which sends air into the passenger compartment normally with the pre-set flows, but this air is at the outside temperature and is not cooled.

Results of the tests
0PRELIMINARY CHECKSAll OKProblems metOperation

1.6 16v

Air Conditioner

Check the condition of the compressor drive beltContinue to Step 1Tension incorrectReplace the belt Op. 1092D10

1.9 JTD 8V

Air Conditioner

Continue to Step 1
1COMPRESSOR ENGAGEMENT CHECKAll OKProblems metOperation
Using the diagnostic equipment (Examiner or other instruments) carry out the active diagnosis of the operation of the compressore relay (in the engine management control unit ambient)Continue to Step 2Compressore relay faultyCheck and, if necessary, replace the compressor engagement relay
Component defectiveReplace the component involved (if a fuse is involved, search for the cause of the problem)
Connections not correctRestore the connections between engine management control unit, relay and compressor coupling See E6021 COMPRESSOR ENGAGEMENT
2CHECK COMPRESSOR ACTIVATION ELECTRICAL CIRCUITAll OKProblems metOperation

Check, in order:

Continue to Step 3Connections not correctRestore the connections
Pressure switch defectiveReplace the pressure switch Op. 5040B14
Antifrost thermostat defectiveReplace antifrost thermostat Op. 5040B64
Control defectiveChange control unit Op. 7065C10
3CHECK COMPRESSOR ELECTRO-MAGNET COUPLINGAll OKProblems metOperation
Check the operation of the compressor electro-magnet coupling and, in particular, that it is correctly connected to earthContinue to Step 4Compressor electro-magnet coupling malfunctionReplace the compressor Op. 5040A20complete with electro-magnet coupling
4SYSTEM PRESSURE CHECKAll OKProblems metOperation
Check the system pressure: See Test 5040B Check on operation of air conditioning system (pressures)Continue to Step 5High pressure does not increase or low pressure decreases too much: leaks in the circuitLocate these leaks Op. 5040A14, then restore the condition of the circuit
High pressure continues to increase: and the compressor cooling fan does not operate.See table D31
5CHECKING CORRECT OPERATIONAll OKProblems metOperation

Check that there are no reasons why the climate control control unit or the engine control unit do not enable the engagement of the cooling circuit.

For more details see DESCRIPTION AND OPERATION: 5040 AIR CONDITIONING CASING AND COMPONENTS

End of diagnosisFault persistsSearch for the fault starting from another symptom'