Fault diagnosisHeater recirculation not working
HEATER RECIRCULATION NOT WORKING
The recirculation function is not working properly
| Results of the tests | ||||
| 1 | CHECK RECIRCULATION CONTROL | All OK | Problems met | Operation |
|---|---|---|---|---|
Check the recirculation control cable is correctly fitted. Check the recirculation flap moves freely. | Continue to Step 2 | Connection defective | Adjust correction or change the cable Op. 5020B35 | |
| Flap blocked or defective | Restore the flap to working order or replace Op. 5020A24 | |||
| Air recirculation control defective | Change control unit Op. 7065C10 | |||
| 2 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | End of diagnosis | Fault persists | Search for the fault starting from another symptom' | |