01 General information02 Specifications03 Manufacturing data and tolerances04 Tightening torques05 Fluids and lubricants06 Maintenance07 Diagnostic checks08 Engine09 Clutch10 Gearbox and differential11 Axles and driveshafts12 Brakes13 Steering14 Suspension and wheels15 Heating, air conditioning and auxiliary units16 Electrical equipment17 Body fittings18 Body panels and frame19 Wiring diagrams and electrical functions20 Wiring harnesses21 Connectors and pin-outs22 Fault diagnosis23 Special tools
Fiat Multipla Factory Service Manual (1998-2010)22 · Fault diagnosis
22 · Diagnostics

Engine does not switch to gas

Make
Fiat
Model
Multipla Factory Service Manual
Year
1998–2010
Section
Engine › Engine does not switch to gas
Fault diagnosisEngine does not switch to gas

ENGINE DOES NOT SWITCH TO GAS

1.6 16v · GPOWER

The engine starts normally on petrol, but does not then switch to gas.

Results of the tests
0PRELIMINARY CHECKSAll OKProblems metOperation

Preliminarily check:

  • that there is LPG in the tank
Continue to Step 1LPG level insufficientRestore the correct LPG level
1CHECKING WITH DIAGNOSTIC EQUIPMENTAll OKProblems metOperation

Connect the Examiner diagnostic equipment to the diagnostic connector and check the petrol and LPG engine management control unit: in errors ambient

  • that there are no faults in the petrol and LPG engine management control units

In parameters ambient

  • the plausibility of all the parameters
Continue to Step 3Error detected in the petrol engine management control unitContinue following the instructions for the diagnostic equipment
Error detected in the LPG engine management control unitProceed as indicated on the tester
Failed dialogue between the petrol engine management control unit and the LPG engine management control unitRestore the connection between the petrol and LPG control units See E5030 PETROL ENGINE ELECTRONIC MANAGEMENT
No connection to earth for LPG control unitRestore the earth connection See E5030 PETROL ENGINE ELECTRONIC MANAGEMENT
LPG pressure greater than or equal to 20 barContinue to Step 2
2LPG LEVEL SENSOR FLOAT AND 80% TANK FILLING VALVE CHECKAll OKProblems metOperation

Detach the LPG tank, drain it by sending it to an authorized centre and check the following:

Continue to Step 380% Filling valve faulty80% tank filling valve Op. 1043A24
Float defectiveReplace the float Op. 1043A62
3GAS/PETROL SELECTOR BUTTON CHECKAll OKProblems metOperation

Using the Examiner diagnostic equipment connected to the diagnostic connector, check the following at the engine management control unit: in errors ambient

  • that the GAS/Petrol switch is working properly

Check the operation of the GAS/Petrol switch See Test 1057A Petrol/LPG switch operation check

Continue to Step 4GAS/PETROL switch defectiveReplace switch
Wiring brokenRenew the wiring See E5030 PETROL ENGINE ELECTRONIC MANAGEMENT
Selector supply interruptedRestore the continuity of the wiring See E5030 PETROL ENGINE ELECTRONIC MANAGEMENT
LPG control unit defectiveReplace the LPG control unit Op. 1057B80
4LPG LEVEL SIGNAL CHECKAll OKProblems metOperation

Check, in order:

Continue to Step 5LPG level sensor supply not correctRestore correct supply See E5030 PETROL ENGINE ELECTRONIC MANAGEMENT
LPG level sensor defectiveReplace the LPG level sensor Op. 1043A60
LPG sensor float faultyReplace the float Op. 1043A62
5LPG PRESSURE CHECKAll OKProblems metOperation

Check, in order:

Continue to Step 6LPG pump defectiveReplace the LPG pump Op. 1043A57
LPG pump control unit defectiveReplace the LPG pump control unit Op. 1043A54
Pressure sensor defectiveReplace the pressure regulator Op. 1043B42
Faulty wiringRenew the wiring See E5030 PETROL ENGINE ELECTRONIC MANAGEMENT
6ENGINE MANAGEMENT CONTROL UNITS CAN CONNECTING LINE CHECKAll OKProblems metOperation
Check the continuity/insulation of the CAN line connecting the petrol engine management control unit and the LPG engine management control unit See E5030 PETROL ENGINE ELECTRONIC MANAGEMENTContinue to Step 7CAN line interruptedRestore continuity See E5030 PETROL ENGINE ELECTRONIC MANAGEMENT
CAN line short circuitedRepair the insulation See E5030 PETROL ENGINE ELECTRONIC MANAGEMENT
7CHECK ON CORRECT OPERATIONAll OKProblems metOperation
Check that the fault is no longer presentEnd of diagnosis

Parts & tools for this job For 1998 Fiat Multipla