Engine starts, and cuts out straight away
- Make
- Fiat
- Model
- Multipla Factory Service Manual
- Year
- 1998–2010
- Section
- Starting › Engine starts, and cuts out straight away
Fault diagnosisEngine starts, and cuts out straight away
ENGINE STARTS, AND CUTS OUT STRAIGHT AWAY
The engine starts, with difficulty and then immediately cuts out suddenly
| Results of the tests | ||||
| 0 | PRELIMINARY CHECKS | All OK | Problems met | Operation |
|---|---|---|---|---|
Preliminarily check:
| Continue to Step 1 | Presence of dirt in the fuel tank | Clean the fuel tank Op. 1040A10 | |
| Spark plugs dirty or damaged | Clean or replace the spark plugs Op. 5510D10 | |||
| Spark plug leads damaged | Replace the spark plug leads Op. 5510D14 | |||
| Air intake circuit component damaged | Replace the component (see Assembly 1048A) | |||
| Catalyzer obstructed | Replace the catalyzer Op. 1080B62 | |||
| 1 | CHECK WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
| Connect the diagnostic equipment (Examiner or other instruments) to the diagnostic socket Check that there are no fault in the engine management control unit | Continue to Step 2 | An error is detected in the control unit | Continue according to the instructions for the diagnostic equipment | |
| Lack of dialogue with the control unit | Restore the connection between the engine management control unit and the diagnostic connector ( See E5030 PETROL ENGINE ELECTRONIC MANAGEMENT). | |||
| 2 | COILS CHECK | All OK | Problems met | Operation |
| Using the diagnostic equipment (Examiner or other iinstruments), carry out the active diagnosis of the coils | Continue to Step 3 | Coils connection faulty | Restore the connection for the coils with the control unit, ( See E5030 PETROL ENGINE ELECTRONIC MANAGEMENT) | |
| Ignition coils faulty | Replace the ignition coils Op. 5510C14 | |||
| 3 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | End of diagnosis | Fault persists | Search for the fault starting from another symptom' | |
The engine starts, with difficulty and then immediately cuts out suddenly
| Results of the tests | ||||
| 0 | PRELIMINARY CHECKS | All OK | Problems met | Operation |
|---|---|---|---|---|
First check that there is fuel in the tank Then check:
| Continue to Step 1 | Presence of dirt in the fuel tank | Clean the fuel tank Op. 1040A10 | |
| Air intake circuit component damaged | Replace the component (see Assembly 1048A) | |||
| 1 | CHECK WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
Connect the diagnostic equipment (Examiner or other instruments) to the diagnostic socket Check:
| Continue to Step 2 | An error is detected in the control unit | Continue according to the instructions for the diagnostic equipment | |
| Lack of dialogue with the control unit | Restore the connection between the engine management control unit and the diagnostic connector ( See E5050 DIESEL ENGINES ELECTRONIC MANAGEMENT). | |||
| 2 | FUEL FILTER CHECK | All OK | Problems met | Operation |
| Check the condition and the cleanliness of the fuel filter: | Continue to Step 3 | Filter dirty | Replace the filter element Op. 1044B20 Restore the condition of the filter, the pipes and the heater device | |
| Filter faulty or damaged | Replace the filter Op. 1044B10 | |||
| 3 | LOW PRESSURE CHECK | All OK | Problems met | Operation |
| Check the fuel supply circuit, low pressure side: if necessary, use the diagnostic equipment (Examiner) to measure the pressure values | Continue to Step 4 | Pressure not correct: fuel filter faulty | Replace the fuel filter Op. 1044B10 | |
| Pressure not correct: electric pump faulty | Replace the electric pump Op. 1040A70 | |||
| Pressure not correct: low pressure pipes faulty | Replace the low pressure pipes (see Assembly 1060F) | |||
| 4 | HIGH PRESSURE CHECK | All OK | Problems met | Operation |
| Check the fuel supply circuit, high pressure side: for example, using the diagnostic equipment (Examiner) to measure the pressure values | Continue to Step 5 | Pressure not correct: pressure pump faulty | Replace the pressure pump Op. 1060E10 | |
| Pressure not correct: manifold faulty | Replace the manifold Op. 1060F30 | |||
| Pressure not correct: injectors faulty | Replace the injectors Op. 1060F10 | |||
| Pressure not correct: high pressure pipes faulty | Replace the high pressure pipes (see Asembly 1060F) | |||
| 5 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | End of diagnosis | Fault persists | Search for the fault starting from another symptom' | |
Parts & tools for this job For 1998 Fiat Multipla
- PARTEngine gasket setSearch: Fiat Multipla 1998 engine gasket set
- TOOLTorque wrenchSearch: 3/8 inch torque wrench
- TOOLFeeler gauge setSearch: feeler gauge set
Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.