Fault diagnosisDisplay of fault in headlamp adjuster on matrix
DISPLAY OF FAULT IN HEADLAMP ADJUSTER ON MATRIX
The Headlamp Alignment Failure message is displayed through a direct command between the Headlamp Alignment Corrector and the Instrument Panel Node
| Results of the tests | ||||
| 1 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
|---|---|---|---|---|
| Connect the Examiner diagnostic equipment to the diagnostic connector and check that there are no faults in the errors ambient at the headlamp alignment correction control unit | Continue to Step 3 | Presence of faults | Continue as instructed by the tester | |
| Warning light faulty | Continue to Step 2 | |||
| 2 | CHECKING ELECTRICAL EQUIPMENT | All OK | Problems met | Operation |
| Check the electrical connection (continuity/insulation to earth) between the Headlamp Alignment Correction Control Unit and the Instrument Panel Node See E4010 INSTRUMENT PANEL | Continue to Step 3 | Cable directly earthed/broken | Renew the electrical connections See E4010 INSTRUMENT PANEL | |
| 3 | Continue as instructed by the tester | All OK | Problems met | Operation |
| Check that the fault is no longer present | End of diagnosis | Fault persists | Replace the instrument panel Op. 5560B11 | |
‹ Prev M.i.l warning light stays on / engine startsNext › Climate control not working / under no circumstances