ELECTRIC SLIDING SIDE DOORS NOT WORKING
The sliding side doors (NPS) open manually but not automatically (electric operation).
The vehicle uses a door activation and deactivation system with the transfer of data via special CAN/VAN networks. The command for opening the door lock motors depends on the Body Computer.
If the ABS is faulty, the side doors do not open automatically with the engine running.
| STEP | OPERATIONS TO BE CARRIED OUT | TEST RESULTS | ||
|---|---|---|---|---|
| 0 | PRELIMINARY CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Check that the battery voltage is correct. | Move on to Step | Battery voltage not correct. | Restore the correct voltage. | |
| 1 | CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Connect the Examiner diagnostic equipment and check for the parameters in the "Texton sliding doors" PLS ambient | Move on to Step | 1. Impossible to connect with the control unit. | Move on to Step | |
| 2. Control unit error. | Move on to Step | |||
| 2 | NETWORK EFFICIENCY CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Connect the Examiner diagnostic equipment to check the efficiency of the VAN Car2 network by connecting to one of the other nodes in the same branch, such as: driver''s door node NPG, passenger door node NPP, sun roof nod NTA, particle filter node NAD, seats node NAG, alarm node NAL | Move on to Step | Connection with one or more "nodes" cannot be made, VAN Car2 network or Body Computer faulty. | Continue following the instructions for the central locking fault diagnosis | |
| 3 | ELECTRICAL SYSTEM NETWORK CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
Check for a positive power supply (battery) at the VAN Car2 network twin connection with the PLS node | Move on to Step | 1. Power supply not working properly, wiring faulty | 1. Repair the wiring | |
| 2. Control unit faulty causing short circuit. | 2. Replace the Sliding Door Node control unit. | |||
| 4 | CHECK USING DIAGNOSTIC EQUIPMENT | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| After having started the engine, connect the Examiner diagnostic equipment and check the activation of the system in the PLS Texton Sliding Doors ambient using Active Diagnosis. | Move on to Step | 1. Side door(s) opening/closing faulty in Active Diagnosis. | Move on to Step | |
| 2. The buzzer does not sound in Active Diagnosis. | 2. Replace the Sliding Door Node control unit. | |||
| 5 | ELECTRICAL SYSTEM CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
Check efficiency of the positive power supply (battery Pin 1/8) for the PLS node | Move on to Step | 1. Fuse/s blown | 1. Eliminate short circuits and then change fuse/s | |
| 2. Power supply not working properly, wiring not working properly. | 2. Repair the wiring | |||
| 6 | ELECTRICAL SYSTEM CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Check efficiency of the PLS node earth (Pin 9 / 16) | Move on to Step | Earth inefficient | Repair the connection | |
| 7 | CHECK ON CORRECT OPERATION | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Check that the fault is no longer present | Fault persists | Continue following the instructions in Table P051 | ||