CAUTION:Do not touch the watershield adhesive surfaces as re-bonding will be impaired.
Locally peel back the trim watershield.
Using a plastic knife, (disposable cutlery) cut through the Butyl strip to enable the protective sheet to be peeled back for access. Do not attempt to peel the sheet from the door without cutting the butyl.
Unclip and detach the remote control lever and cable from the door.
Remove the three lock retaining screws.
Ease the lock out from the door and disconnect the lock motor multiplug.
Unclip the lock motor loom from the lock cover.
Remove the lock cover shield.
Remove the two screws and unclip the cover from the lock.
Disconnect the door ajar switch.
Push in and tilt up to remove.
Disconnect the remote lever cable from the lock.
Pull the outer cable from the lock bracket.
Align the inner cable with the slot in the actuator lever and lift out.