isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Valve Cover|Service and Repair|Page 1623 > < Valve Cover|Service and Repair|Page 1621
Page 3
background image

3. Install the radiator inlet hose to the water outlet.
4. Fill the cooling system.
5. Install the PCV valve hose assembly to the valve rocker arm cover.
6. Connect the ECT sensor.
7. Install the air cleaner assembly.
8. Install the air cleaner outlet duct to the throttle body.

Valve Rocker Arm Cover Replacement (Right) 

Removal Procedure
1. Remove the PCV tube from the air cleaner outlet duct and the valve rocker arm cover.
2. Disconnect the spark plug wires from the spark plugs for the right side of the engine. 
3. Remove the EVAP canister purge solenoid valve. 
4. Unfasten the heater hose retainer above the valve rocker arm cover.
5. Move and secure the heater hoses aside.

6. Remove the bolt holding the engine wiring harness bracket to the generator.
7. Disconnect the crankcase position (CKP) sensor electrical connector.
8. Move and secure the engine wiring harness aside.

Valve Cover|Service and Repair|Page 1623 > < Valve Cover|Service and Repair|Page 1621