new switch kit has the O-ring and retainer ring included.

Install or Connect

1. Check switch cavity and O-ring groove in the rear head for dirt or foreign material and clean as necessary. Install a new O-ring coated with clean

refrigerant oil into groove in switch cavity.

2. Lubricate the control switch housing with clean refrigerant oil and carefully insert switch into switch cavity until switch bottoms in cavity.
3. Using J 9533-1 snap ring pliers install switch retaining ring with high point of curved sides adjacent to switch housing. Be sure retaining ring is

properly seated in switch cavity retaining groove. Leak test according to bench test procedure.