Workshop Manuals Factory service & repair Mazda
01 Relays and Modules02 Sensors and Switches03 Maintenance04 Engine, Cooling and Exhaust05 Powertrain Management06 Transmission and Drivetrain07 Brakes and Traction Control08 Starting and Charging09 Power and Ground Distribution10 Steering and Suspension11 Heating and Air Conditioning12 Restraint Systems13 Accessories and Optional Equipment14 Body and Frame15 Cruise Control16 Instrument Panel, Gauges and Warning Indicators17 Lighting and Horns18 Windows and Glass19 Wiper and Washer Systems
Mazda Millenia V6-2.5L DOHC (1999)08 · Starting and Charging
08 · Electrical

Battery (Battery Specifications): Specifications

Make
Mazda
Model
Millenia
Engine
V6-2.5L DOHC
Year
1999
Section
Battery › Specifications › Battery Specifications
Starting and ChargingBattery Specifications · page 1 of 2
background image

Battery: Specifications
Battery Specifications

Battery Specifications 

Open Circuit Voltage

Above 12.4 V 

   

  

  

 

Test Load Chart 

   

   

  

 

Battery

Load (A) 

   

  

  

 

55D23L

180 

   

  

  

 

75D23L

195 

   

  

  

 

80D26L

195 

   

  

  

 

Battery Voltage With Load 

   

       

  

 

Approximate Battery Temperature Minimum Voltage (V) 

   

  

  

 

21 degrees C (70 degrees F)

9.6 

   

  

  

 

15 degrees C (60 degrees F)

9.5 

   

  

  

 

10 degrees C (50 degrees F)

9.4 

   

  

  

 

4 degrees C (40 degrees F)

9.3 

   

  

  

 

Charging Current 

   

            

  

 

Battery Type (5 Hour Rate)

Slow Charge (A)

Quick Charge (A) 

   

  

  

 

55D23L (48)

4.5-5.5

30 

   

  

  

 

75D23L (52)

5.0-6.0

35 

   

  

  

 

80D26L (55)

5.5-6.5

35 

   

  

  

 

Battery Positive Voltage

Above 12.4 V 

   

  

      

 

Pinch or Ctrl + scroll to zoom. Double-tap to reset.

Parts & tools for this job For 1999 Mazda Millenia 2.5L

Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.