PREPARATION
SST
| For inspection of radiator cap valve | For inspection of radiator cap valve | ||
| 49 9200 145 Adapter set, radiator cap tester |
49 9200 147 Adapter B (Part of 49 9200 145) |
INSPECTION
Radiator Cap Valve
- Remove foreign material (such as water residue) from between the radiator cap valve and the valve seat.
- Attach the radiator cap to a radiator cap tester (commercially available) with the SST. Apply pressure gradually to 74—103 kPa (0.75—1.05 kg/cm², 11—15 psi).
- Wait about 10 seconds. Verify that the pressure has not decreased.
Negative Pressure Valve
- Pull the negative pressure valve to open it. Verify that it closes completely when released.
- Check for damage on the contact surfaces and for cracked or deformed seal packing.
- Replace the radiator cap if necessary.