Step 4
- Make
- Mazda
- Model
- MX-5 (NA) Factory Workshop Manual
- Year
- 1990–1992
- Section
- [T] › Step 4
Body electrical systemStep 4
Step 4
- Disconnect the backup battery connector.
- Reconnect the negative battery cable.
- Measure the voltage at terminal-wire (G/R) of the backup battery connector.
| Wire | Voltage | Action |
|---|---|---|
| (G/R) | 12V | Go to Step 5 |
| 0V | Replace wire harness assembly |
Step 5
- Disconnect the negative battery cable.
- Disconnect the diagnostic module connector.
- Reconnect the negative battery cable.
- Measure the voltage at the terminal-wires of the diagnostic module connector.
| Terminal-wire | Voltage | Action |
|---|---|---|
| 1L (W/G) | 12V | Next, check terminal-wire 1J (G/Y) |
| 0V | Replace wire harness assembly | |
| 1J (G/Y) | 12V | Replace diagnostic module |
| 0V | Replace wire harness assembly |
Parts & tools for this job For 1990 Mazda MX-5
- TOOLDigital multimeterSearch: automotive digital multimeter
- PARTAssorted fuse kitSearch: car fuse assortment kit
- TOOLWire crimper and connector kitSearch: wire crimper connector kit