01 Introduction02 General information03 Information04 Maintenance05 Engine06 Engine management system - MEMS07 Cooling system08 Manifold & exhaust systems09 Clutch10 Manual gearbox11 Automatic gearbox - EM-CVT12 Drive shafts13 Steering14 Suspension15 Brakes16 Restraint systems17 Body18 Heating & ventilation19 Air conditioning20 Wipers & washers21 Electrical22 Instruments
MG MGF Factory Workshop Manual (1995-2000)19 · Air conditioning
19 · Heating & A/C

Air conditioning (Performance Guide-lines): Adjustments

Make
MG
Model
MGF Factory Workshop Manual
Year
1995–2000
Section
Adjustments › Performance Guide-lines
Air conditioningPerformance Guide-lines

Performance Guide-lines

Carry out this test with bonnet, doors or windows open; air conditioning switched on, temperature control set to cold, face vent mode and blower at maximum speed. Set the air supply control to supply fresh air.

  1. Close low pressure valve on Refrigerant Station.
  2. Close high pressure valve on Refrigerant Station.
  3. Connect Refrigerant Station to the high and low pressure servicing connections.
  4. With a thermometer measure the air intake temperature, close to the outside air inlet at the plenum.
  5. With a thermometer measure the air outlet temperature, at the centre vent outlet.
  6. Run the engine at idle speed for 10 minutes or until normal operating temperature is reached.
  7. Read both pressure gauges and thermometers. Check readings against the guide-lines shown in the table below.
Ambient20°C25°C30°C35°C40°C
Outlet Temperature (°C)5 - 107 - 158 - 2011 - 2214 - 25
Low Pressure (bar)1.6 - 2.41.8 - 2.62.0 - 3.22.2 - 3.52.4 - 3.8
High Pressure (bar)14 - 1914 - 1914 - 2118 - 2319.6 - 24.8
NotesA + BA + BA + BBB

NOTES

  • The temperatures and pressures may be slightly increased for high humidity conditions.
  • The varying air conditioner pressure will dictate whether the fans operate in series or parallel, which will itself cause the temperatures and pressures to fluctuate. For example: A =Condenser and cooling fan both running at half speed (series) B =Condenser and cooling fan both running at full speed (parallel) A + B =Fans switching from series to parallel.