Refrigerant recovery, recycling and recharging (Air conditioning)
- Make
- MG
- Model
- MGF Factory Workshop Manual
- Year
- 1995–2000
- Section
- Adjustments › Refrigerant recovery, recycling and recharging
Air conditioningRefrigerant recovery, recycling and recharging
REFRIGERANT RECOVERY, RECYCLING AND RECHARGING
NOTE: An air conditioning portable Refrigerant Recovery, Recycling and Recharging Station for use with R134a refrigerant incorporates all the features necessary to recover refrigerant R134a from the A/C system, to filter and remove moisture, to evacuate and recharge with reclaimed refrigerant. The unit can also be used for performance testing and air conditioning system analysis.
Service connections
- High pressure
- Low pressure
Parts & tools for this job For 1995 MG MGF
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: MG MGF 1995 cabin filter