mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2117 > < Initial Inspection and Diagnostic Overview|Page 2115
Page 85
background image

Q: Is the power window sub-switch normal?

YES: Go to Step 4.

NO: Replace the power window sub switch. When the power window sub-switch is operated, the power window (RH) should open or close
normally.

STEP 4. Check the front power window motor (RH).

1. Remove the front power regulator assembly (RH). Refer to Door - Door Glass and Regulator.

2. Connect a battery to the motor terminal, and check that the motor runs freely.

Q: Is the front power window motor (RH) normal?

YES: Go to Step 5.

NO: Replace the front power regulator assembly (RH). When the power window sub-switch is operated, the power window (RH) should open
or close normally.

STEP 5. Check at front power window sub-switch connector E-05 in order to check the power window relay circuit of the power supply to the
power window sub-switch.

1. Disconnect power window sub-switch connector E-05, and measure at the harness side.

2. Measure the voltage between terminal 7 and ground.

-

The measured value should be approximately 12 volts (battery positive voltage).

 

Q: Does the measured voltage correspond with this range?

YES: Go to Step 8.

NO: Go to Step 6.

Initial Inspection and Diagnostic Overview|Page 2117 > < Initial Inspection and Diagnostic Overview|Page 2115