Workshop Manuals Factory service & repair Pontiac
01 Relays and Modules02 Sensors and Switches03 Maintenance04 Engine, Cooling and Exhaust05 Powertrain Management06 Transmission and Drivetrain07 Brakes and Traction Control08 Starting and Charging09 Power and Ground Distribution10 Steering and Suspension11 Heating and Air Conditioning12 Restraint Systems13 Accessories and Optional Equipment14 Body and Frame15 Cruise Control16 Instrument Panel, Gauges and Warning Indicators17 Lighting and Horns18 Windows and Glass19 Wiper and Washer Systems
Pontiac G8 V8-6.0L (2009)03 · Maintenance
03 · Maintenance

Refrigerant Oil: Specifications (page 2 of 3)

Make
Pontiac
Model
G8
Engine
V8-6.0L
Year
2009
Section
Fluids › Refrigerant Oil
MaintenanceSpecifications · page 2 of 3
background image

Refrigerant Oil: Service and Repair

Air Conditioning (A/C) System Oil Charge Replenishing

Tools Required

J 41459  A/C Oil Injector

Important:  The addition of lubricating oil must be carried out whenever any component is replaced in the A/C system to compensate for
oil trapped in the removed component. Carrying out this procedure ensures the A/C system always has the correct amount of oil as
specified by the manufacturer.

1. Evacuate the A/C system for a minimum of 30 minutes and to minus 100 kPa negative gauge pressure. Refer to Refrigerant Recovery and

Recharging   (See: Heating and Air Conditioning/Service and Repair/Procedures/Refrigerant Recovery and Recharging).

Important:  Make sure the valve (3) is in the closed position.

2. Remove the plunger (1) from the J 41459    (2) and pour in the appropriate amount of polyalkylene glycol (PAG) oil specified for the replaced

component. Refer to Refrigerant System Capacities   (See: Heating and Air Conditioning/Specifications/Capacity Specifications).

3. Jiggle the plunger (1) to remove any air in the J 41459    (2).

4. With the A/C system still evacuated, connect the J 41459    (1) to the low side charging port (2).
5. Turn the J 41459   shut off valve tap (3) to the open position to depress the low side charging port (2) schrader valve.

The oil should now be drawn into the A/C system due to the low pressure in the A/C system.