re-filled prior to use! The procedure is described in detail in the course of the repair instructions.

Filling the air-spring strut

Caution:
Increased risk of accident due to compressed gas bottles under high pressure (up to 200 bar).
-

Injuries and material damage are possible.

-

Observe the relevant operating regulations for handling compressed air and gas filling units.

-

Observe accident prevention regulations.

Information 
-

Do not remove air-spring strut from transport packaging until it has been filled. This will prevent damage to the inner bellows.

-

The air-spring strut must be screwed securely in the transport packaging during filling.

-

During assembly work, make sure that there are no pressure marks on the protective boot of the air-spring strut.

-

After installation, first set the high level, then go to normal level. Repeat this procedure once more. This procedure replaces most of the gas with
the cleaned air from the air supply unit. is filled with Argon or Corgon!)

1. Remove transport packaging lid..
2. Pull off protective cap on residual pressure retaining valve. Carefully remove any left-over packaging.
3. Pull off plug connection on residual pressure retaining valve (a/f 12) and screw on the filling unit adapter T10157/1 at the correct position on the

residual pressure retaining valve.

Information 
-

The air-spring strut must only be filled with the approved gasses, dual-process gasses Argon and Corgon.

-

In isolated cases, up to 11 bar overpressure (upper tolerance, spring strut depressurized) is required to open the residual pressure retaining valve.

-

Fill the air-spring strut using several individual pressure shots. Filling the air with individual pressure shots will prevent the air-spring strut from
being filled with too much overpressure.

-

Do not fill the air-spring strut with overpressure of more than 4.5 bar.

-

The residual pressure retaining valve automatically reduces excessive overpressure to the minimum overpressure of approx. 3 bar.

4. Fit the filling unit to the pressure gauge unit of the compressed air bottle.

5. Set the pressure gauge unit (flow limiter) to approx. 20 l/min -arrow- .