Evacuation and recharging (Air conditioning)
- Make
- Rover
- Model
- 600 620 Diesel Repair Manual Supplement
- Year
- 1995–1999
- Section
- Adjustments › Evacuation and recharging
Evacuation and recharging
- Add calculated refrigerant oil to the compressor as necessary.
- Renew receiver/drier.
- Connect a Refrigerant Station to the high and low pressure servicing connections.
CAUTION: Whenever the refrigerant system is opened, the receiver/drier must be renewed immediately before evacuating and recharging the system.
- Operate the refrigerant evacuation system according to the manufacturers instructions.
NOTE: If the vacuum reading is below 700 mm/Hg after 15 minutes, suspect a leak in the system. Partially recharge the system and check for leaks using an electronic leak tester.
CAUTION: The system must be evacuated immediately before recharging commences. Delay between evacuation and recharging is not permitted.
- Operate the refrigerant recharging system according to the manufacturers instructions.
Refrigerant required to charge system is: LHD vehicles - 650 grammes ± 50 grammes RHD vehicles - 700 grammes ± 50 grammes
- If the full charge has not been accepted by the system, start the engine and run it at 1500 rev/min.
- Switch on the air conditioning system, open the car windows, set the temperature control to cold and switch the blower to maximum speed.
- Consult the Refrigerant Station Manual for the correct procedure to complete the charge.
- Carry out the air conditioning system performance test.
Parts & tools for this job For 1995 Rover 600
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Rover 600 1995 cabin filter
Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.