Check refrigerating output
- Make
- SEAT
- Model
- Altea / Altea XL / Freetrack
- Year
- 2004–2015
- Section
- Heating, air conditioning › Check refrigerating output
Check refrigerating output
Measure ambient temperature (it must be over 15℃).
Close doors, bonnet, windows and sunroof.
Open all dash panel vents.
Switch on ignition.
Vehicles fitted with Climatronic:
Select the „Econ“ mode on the Climatronic control unit J255.
Vehicles fitted with Climatic:
The button „AC“ should not be activated.
Start the engine.
Finish the air conditioning self-diagnosis Vehicle diagnostic tester.
Select the function „ Read measurement value block“. Check the corresponding measurement value blocks for the refrigerant circuit pressure Vehicle diagnostic tester.
Check the indication in the display fields:
| Ambient temperature in °C | Displayed pressure (in bar absolute) |
|---|---|
| 15 | 4,7 |
| 20 | 5,6 |
| 25 | 6,6 |
| 30 | 7,6 |
| 35 | 8,8 |
Note
- An absolute pressure of 0 bar represents an absolute vacuum. The normal ambient pressure is therefore equivalent to approx. 1 bar absolute pressure. In general most manometer scales represent atmospheric pressure as 0 bar meaning an absolute pressure of 1 bar (this can be recognised if there is a -1 on the scale).
- The pressure in the refrigerant circuit depends on the ambient temperature. Due to heat radiation from components (for example the coolant radiator), for a warm engine at normal running temperature, the indicated pressure is a above the corresponding atmospheric temperature.
- If the displayed pressure is lower than that given in the table:
- High pressure sender G65Chapter “Checking the pressure signal of the High pressure sender G65.”.
- If no fault is found at high-pressure sender, there is not enough refrigerant in the circuit and vehicle must be taken to a specialist air conditioner workshop.
If pressure in refrigerant circuit is OK.
Vehicles fitted with Climatronic:
Switch on the compressor by adjusting the operating mode „Auto“ on the Climatronic control unit J255.
Select the lowest temperature setting (for driver and passenger side) on the Climatronic control unit J255.
Adjust air outlet direction on the Climatronic control unit J255 to the „dashboard vents“.
Vehicles fitted with Climatic:
With the button „AC“ pressed, the speed „1“ of the Fresh air blower V2 is selected along with the lowest possible temperature.
Adjust air direction to the „instrument panel vents“
All vehicles (continued):
Select the function „ Read measurement value block“Vehicle diagnostic tester.
Check in the corresponding indication fields for a duty cycle of more than 30% (the Compressor regulation valve, air conditioning N280 is activated, the compressor is running), and a current intensity of more than 0.3 A (current flows through the Compressor regulation valve, air conditioning N280, the compressor is operating)
Pressure in the refrigeration circuit rises above value with compressor off.
Note
- Compressor regulation valve, air conditioning N280 is operated by the Climatronic control unit J255/Air conditioning control unit J301 in such a way that the air temperature reaches the specified value (approx. 2 to 5℃) after the evaporator:
- After starting the vehicle, a value greater than 75 % (0.55 A) is displayed depending on the measured temperature, engine speed and electrical system voltage.
- Air temperature sender, evaporator output G263 approaches the specification, the activation is reduced as is the compressor performance.
- Under certain conditions of use, ice may form on the regulation valve for the compressor (and on the expansion valve) because of humidity on the refrigeration circuit. Due to the formation of this ice, the regulation of the compressor is inhibited, the evaporator is cooled too much and will freeze. Freezing of the evaporator can lead to the following complaints:
- After a longer driving period, the air conditioner fails several times or every now and then (no cooling or heating performance). The function of the air conditioner is okay again after turning off the vehicle and after a brief waiting time.
- button does not free the windows from the mist. The function of the air conditioner is okay again after turning off the vehicle and after a brief waiting time.
- Remedy
- Air temperature sender, evaporator G263 function Vehicle diagnostic tester.
- Air temperature sender, evaporator output G263 (the evaporator may freeze because of a measurement value error).
- If the measurement value of the sender is very low under the conditions described by the client (with an atmospheric temperature of more than 0℃, less than 0° for a long time), bring the vehicle to a workshop specialised in air conditioning.
- Check the refrigeration tubes from the evaporator (from the expansion valve) to the compressor (thick tube, low pressure side) while the engine is running. If the pipe is severely iced up by the problem described (thin ice layer is permissible), this is a further indication that the temperature in the evaporator is too low. Bring the vehicle to a workshop specialised in air conditioning.
- The specialist workshop can determine the error. The required work (draining the refrigerant circuit, replacing tanks and then allow the refrigerant circuit to drain for minimum 3 hours) can only be carried out by such specialist workshops.
- Compressor regulation valve, air conditioning N280Chapter “Check the activation signal for the Compressor regulation valve, air conditioning N280”.
- When the pressure displayed in the respective measured value block does not change and the controlling of the compressors is okay, there is a fault in the refrigerant line Bring the vehicle to a workshop specialised in air conditioning.
Press the button for air recirculation on the Climatronic control unit J255/Air conditioning control unit J301 (the symbol for the „air recirculation mode“ lights).
Set engine speed to 2000 rpm (start of time measurement).
Select the function „Read measurement block values“ for the indication group corresponding to the Air temperature sender, evaporator G263.
Compare measured value indicated in display field (of the Air temperature sender, evaporator output G263) to values in the diagram.

Depending on the ambient temperature, the measured ambient temperature must be within the stated tolerance range after 5 minutes.
Note
- Air temperature sender, evaporator G263, compare the measurement values in the corresponding indication fields:
- evaporator outlet temperature sender G263 is greater than the measurement value of the outlet temperature sender, left side G150 and outlet temperature sender, right side G151 or the outlet temperature sender, centre G191, check that the evaporator outlet temperature sender G263 is installed correctly and carry out the electric test for this sensorVehicle diagnostic tester.
- The operation of the air conditioning can be seen for example by the cooling of the rigid refrigerant tube on the low pressure side (thick tube).
If the measurement value of the Air temperature sender, evaporator G263 (and, with this, the refrigeration power) are correct:
Compare the measurement value of the evaporator outlet temperature sender G263 with the measurement value of the outlet temperature sender, left side G150 and des outlet temperature sender, right side G151 or the outlet temperature sender, centre G191.
The measurement value of the outlet temperature sender, left side G150 and the outlet temperature sender, right side G151 or the outlet temperature sender, centre G191 are only allowed to be max. 3°C higher than the value in the displayed field of the evaporator outlet temperature sender G263 after 5 minutes.
Note
- If the required values are not reached, compare the measurement values to each other:
- left temperature flap servomotor V158 and the right temperature flap servomotor V159. : temperature flap control motor V68Chapter “Right temperature flap control motorV159 with potentiometer for right temperature flap control motorG221: Removing and installing”, Chapter “Removing and installing temperature flap control motor, left sideV158 with potentiometer for temperature flap control motor, left sideG220, vehicles ¶% 05.2008” and Vehicle diagnostic tester.
- evaporator outlet temperature sender G263, the outlet temperature sender, left side G150 and the outlet temperature sender, right side G151 or the outlet temperature sender, centre G191 are installed correctly and determine if the electrical connections have contact resistance. If necessary, renew defective sensor Vehicle diagnostic tester.
- outlet temperature sender, left side G150 nor in the outlet temperature sender, right side G151 or in the outlet temperature sender, centre G191 or also in the temperature flap control motor, left side V158 or temperature flap control motor, right side V159 or in the temperature flap control motor V68, perform troubleshooting by increasing the temperature behind the evaporator Chapter “Locating faults in case of an increase in temperature after the evaporator”.
- instrument panel vents can also be measured using a normal thermometer for example.
- If the client complains of different temperatures for the same settings, this could be due to the following:
- Chapter “Air intake and air outlet openings” and Vehicle diagnostic tester.
- Chapter “Check the heating performance of the air conditioning”.
- When fitting the heat exchanger, a sponge seal has been displaced and the air passes around the heat exchanger.
Parts & tools for this job For 2004 SEAT Altea
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: SEAT Altea 2004 cabin filter
As an Amazon Associate we earn from qualifying purchases.