Workshop Manuals Factory service & repair SEAT
01 Technical data02 Self diagnosis, V.A.G Inspection Service03 Engine assy, cylinder block, crankcase04 Enginecrankshaft group, pistons05 Engine cylinder head, valve gear06 Engine lubrication07 Engine cooling08 Fuel supply, gas operation09 Exhaust turbocharger, G-charger10 Fuel preparation system Diesel injection11 Mixture preparation system, electronic inj., Gas12 Exhaust system13 Starter-current supply-CC14 Ignition system, glow plug system15 Clutch, control16 Torque converter17 Gearbox mechanics, operation, construction, diff.18 Gearbox, mechanics, gears, shafts, internal operation19 Automatic gearbox, control, assembly, housing20 Automatic gearbox, gears, control21 Final drive, differential, differential lock22 Front suspension, drive shafts23 Rear suspension, drive shaft24 Wheels, tyres. axle align25 ABS, ADR, TCS, EDL, ESP26 Brake, brake mechanics27 Brakes, hydraulics, regulator, servo28 Steering29 Body front30 Body centre, roof, frame31 Bonnet, flaps, cab, central locking32 Front door, central locking33 Rear door, sliding door, wing doors, central locking34 Sliding roof35 Bumper36 Glazing/window mechanism37 Exterior equipment38 Interior equipment39 Passenger protection40 Trim, noise insulation41 Seat frames42 Seat padding, covers43 Heating44 Air conditioner45 Infotainment46 Windscreen wipe/wash system47 Lights, lamps, switches outside48 Lights, lamps, switches inside, anti-theft system49 Wiring
SEAT Altea / Altea XL / Freetrack (2004-2015)44 · Air conditioner
44 · Heating & A/C

Working on refrigerant circuit

Make
SEAT
Model
Altea / Altea XL / Freetrack
Year
2004–2015
Section
Heating, air conditioning › Working on refrigerant circuit
Air conditionerWorking on refrigerant circuit

Working on refrigerant circuit

Heating, ventilation, air conditioning system · Heating, air conditioning · Instructions for repair work on vehicles with air conditioning and how to work with the refrigerant · Toledo from 2005, Altea · Edition 10.2011

Only work on the refrigerant circuit in well ventilated areas. Note that within a radius of 5 m there must be no assembly pits, manholes or cellar access stairs. Extraction systems are to be switched on.

Reasons:

The refrigerant which emerges is not only colourless and odourless, but also heavier than air and therefore displaces oxygen. If, despite observing all safety precautions, refrigerant gas still escapes, there is a danger of suffocation in badly ventilated rooms or assembly pits which cannot be perceived in advance.

Note

  • The mixture of gas and air which forms when refrigerant gas escapes must not be inhaled. Use is to be made of suitable workshop extractors.

Do not weld, braze or soft-solder any parts of the charged air conditioning system. This also applies to welding and soldering work on the vehicle if there is a danger of air conditioner components becoming hot.

Reasons:

Heat leads to high pressure in the system which may cause the system to burst.

Solution:

Drain refrigerant circuit Chapter “Safety precautions”.

Note

  • Do not repair damaged or leaking parts of the air conditioner by welding or soldering; they should be renewed.

When performing repair work on the air conditioning system, all opened components and line connections of the air conditioning systems must be closed immediately.

Reasons:

If components of the air conditioning system remain open for a longer period of time, humidity will enter the system. Therefore air conditioners which have been left open for a lengthy period cannot be re-filled without renewing parts of the system.

Parts & tools for this job For 2004 SEAT Altea