Working on refrigerant circuit
- Make
- SEAT
- Model
- Altea / Altea XL / Freetrack
- Year
- 2004–2015
- Section
- Heating, air conditioning › Working on refrigerant circuit
Working on refrigerant circuit
Only work on the refrigerant circuit in well-ventilated rooms. Note that within a radius of 5 m there must be no assembly pits, manholes or cellar access stairs. Switch on extraction systems.
Escaping refrigerant is not only transparent and odourless, but also heavier than air, i.e. oxygen is being displaced. If, despite observing all safety precautions, refrigerant gas still escapes, there is a danger of suffocation in badly ventilated rooms or assembly pits which cannot be perceived in advance.
Note
- The mixture of gas and air which forms when refrigerant gas escapes must not be inhaled. Use suitable workshop extractors.
Do not weld, braze or soft-solder any parts of the charged air conditioning system. This also applies to welding and soldering work on the vehicle when the danger exists that parts of the air conditioning system may heat up.
Heat leads to high pressure in the system which may cause the system to burst.
Drain refrigerant circuit Chapter “Safety precautions”.
Note
- Do not repair damaged or leaking parts of the air conditioner by welding or soldering; they should be renewed.
When performing repair work on the air conditioning system, all opened components and line connections of the air conditioning systems must be closed immediately.
If components of the air conditioning system remain open for a longer period of time, humidity will enter the system. If an air conditioning system was kept open for a longer period of time, parts of the system must be renewed before refilling the system.
Parts & tools for this job For 2004 SEAT Altea
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: SEAT Altea 2004 cabin filter
As an Amazon Associate we earn from qualifying purchases.