Air conditioning components: removing and fitting
- Make
- SEAT
- Model
- Ibiza / Córdoba
- Year
- 6L, 2002–2008
- Section
- Heating and air conditioning › Air conditioning components: removing and fitting
Air conditionerAir conditioning components: removing and fitting
Air conditioning components: removing and fitting

- 1 Air conditioning wiring harness
- 2 Upper section of the evaporator housing
Joint between upper and lower sections with screws and with staples on Item “Evaporator housing: removing and fitting” - 3 Support
Threaded union in the module bracket and in the heating unit; 12 Nm
Torque for the air conditioning unit: 5 Nm - 4 Fresh air turbine control unit J126
Removing and fitting Chapter “Fresh air turbine control unit J126 : removing and fitting” - 5 Foam rubber gasket
Replace if it has defects.
Self-adhesive
Stuck to the evaporator housing
Before assembly, remove all traces of adhesive with acetone. - 6 Expansion valve
Assembly overview Chapter “Expansion valve - Assembly overview” - 7 Housing air inlet
With fresh air and air recirculation flap
Fixed on the upper and lower sections of the housing with staples in Fig. “Evaporator housing: removing and fitting” - 8 Gasket
Replace if it has defects.
Self-adhesive
Before assembly, remove all traces of adhesive with acetone. - 9 Dust and pollen filter
Also as a combined filter with the odour filter
Removing and fitting Chapter “Dust and pollen filters: removing and fitting” - 10 Control motor for fresh air and circulating air flap V113
Removing and fitting Chapter “Control motor with outside air and recirculated air flap V154: Removing and installing.”
Fit it into the support - 11 Support
Regulation motor for the fresh air and circulation air flap V113 - 12 Fresh-air fan V2
Removing and fitting Chapter “Removing and installing fresh air blowerr V2” - 13 Support for the fresh air fan V2
Remove the support for the fresh air fan Chapter “Removing and installing fresh air blowerr V2” - 14 Lower section of the evaporator housing
Join lower-upper sections with bolts and with staples Item “Evaporator housing: removing and fitting” - 15 Filter cover
- 16 Distributor housing, lower section
The versions are different in vehicles with and without additional heating element Z35
In vehicles with Z35, there is a through hole for the electrical connections. - 17 Heating element for the secondary heating (PTC) Z35
Removing and fitting Chapter “Installation overview for the heat exchanger / heating element for secondary heating (PTC) Z35” - 18 Heat exchanger
Removing and fitting Chapter “Removing and installing heat exchanger” - 19 Central aerator outlet temperature sender G191 Checking: Select the function “Fault finding guide” on the Vehicle Diagnosis, Testing and Information System VAS 5051 or later models.
Function: controls the distribution of demisting/footwell air and the speed of the exterior air fan according to the temperature of the vent air
Emergency operation in the event of a breakdown: the system continues to operate and takes the reference value +80° C
With seal
Removing and fitting Chapter “Central aerator outlet temperature sender G191 : removing and fitting” - 20 Gasket for evaporator
Note the installation position: The water outlets must face downwards. - 21 Evaporator
Removing and fitting Chapter “Evaporator housing: removing and fitting” - 22 Distributor housing, upper section
In the upper and lower sections of the evaporator housing - 23 Left support
Threaded union in the module bracket, air conditioning unit and central console support; 12 Nm
Torque for the air conditioning unit: 5 Nm
Torque for central console support: 12 Nm - 24 Support for servomotors V68 and V107
Removing and fitting Chapter “Servomotor for de-icing flap V107 and servomotor for temperature flap V68 : removing and fitting” - 25 Servomotor for the temperature flap V68
Removing and fitting Chapter “Servomotor for de-icing flap V107 and servomotor for temperature flap V68 : removing and fitting” - 26 Outlet temperature sender in the footwell G192
Checking: Select the function “Fault finding guide” on the Vehicle Diagnosis, Testing and Information System VAS 5051 or later models.
Function: controls the distribution of demisting/footwell air and the speed of the exterior air fan according to the temperature of the vent air
Emergency operation in the event of a breakdown: the system continues to operate and takes the reference value +80 °C of the water temperature
With seal
Removing and fitting Chapter “Outlet temperature sender in the footwell G192 : removing and fitting” - 27 Servomotor for de-icing flap V107 Checking: Select the function “Fault finding guide” on the Vehicle Diagnosis, Testing and Information System VAS 5051 or later models.
Removing and fitting Chapter “Servomotor for de-icing flap V107 and servomotor for temperature flap V68 : removing and fitting”
After replacing: With the Vehicle diagnosis, testing and information system VAS 5051, or later models, run basic configuration - 28 Evaporator output temperature sender G263 Checking: Select the function “Fault finding guide” on the Vehicle Diagnosis, Testing and Information System VAS 5051 or later models.
Removing and fitting Chapter “Evaporator outlet temperature sender G263 : removing and fitting”