Checking operation
- Make
- SEAT
- Model
- Ibiza / Córdoba
- Year
- 6L, 2002–2008
- Section
- Heating and air conditioning › Checking operation
Checking operation
Connect the connector on the regulation motor for the temperature flap.
Remove the connector (1) from the heating and air conditioning control (2).

Connect the battery voltage with the auxiliary cables of V.A.G. 1594 A on contacts 13 and 16 of the connector (1) and check the operation of the motor.
| Assignment of contacts | |||
| 13 | 16 | ||
| The regulation motor moves to the position “Hot” (cogged section upwards) | + | - | |
| The regulation motor moves to the position “Cold” (cogged section downwards) | - | + | |
Note
- (4) and lower (3) limits.
- If the are anomalies in the operation, suspend the test, remove the regulation motor with the support again and repeat installation.

Install the rest in reverse order.
If the regulation motor has been replaced, the basic configuration must be performed Vehicle diagnosis, testing and information system VAS 5051 VAS 5051 , Vehicle self diagnosis
Parts & tools for this job For 2002 SEAT Ibiza
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: SEAT Ibiza 2002 cabin filter