Workshop Manuals Factory service & repair SEAT
01 Technical data02 Engine assy, cylinder block, crankcase03 Enginecrankshaft group, pistons04 Engine cylinder head, valve gear05 Engine lubrication06 Engine cooling07 Fuel supply, gas operation08 Exhaust turbocharger, G-charger09 Fuel preparation system Diesel injection10 Mixture preparation system, electronic inj., Gas11 Exhaust system12 Starter-current supply-CC13 Ignition system, glow plug system14 Clutch, control15 Torque converter16 Gearbox mechanics, operation, construction, diff.17 Gearbox, mechanics, gears, shafts, internal operation18 Automatic gearbox, control, assembly, housing19 Automatic gearbox, gears, control20 Final drive, differential, differential lock21 Front suspension, drive shafts22 Rear suspension, drive shaft23 Wheels, tyres. axle align24 ABS, ADR, TCS, EDL, ESP25 Brake, brake mechanics26 Brakes, hydraulics, regulator, servo27 Steering28 Body front29 Body centre, roof, frame30 Body, rear31 Bonnet, flaps, cab, central locking32 Front door, central locking33 Rear door, sliding door, wing doors, central locking34 Sliding roof35 Bumper36 Glazing/window mechanism37 Exterior equipment38 Interior equipment39 Passenger protection40 Trim, noise insulation41 Seat frames42 Seat padding, covers43 Heating44 Air conditioner45 Instruments, GCI46 Infotainment47 Windscreen wipe/wash system48 Lights, lamps, switches outside49 Lights, lamps, switches inside, anti-theft system50 Wiring
SEAT Ibiza / Córdoba (6L, 2002-2008)44 · Air conditioner
44 · Heating & A/C

Checking

Make
SEAT
Model
Ibiza / Córdoba
Year
6L, 2002–2008
Section
Heating and air conditioning › Checking
Air conditionerChecking

Checking

Heating, ventilation, air conditioning system · Heating and air conditioning · Air-conditioning, climate control · Ibiza from 2002 · Edition 02.2008

Measure the ambient temperature (must be greater than 15°C).

Close doors, bonnet, windows and sun roof.

Close “right” and “left” air inlets on the dashboard.

Switch on ignition.

Select operating mode “Econ” on the E87 (the light on the “Econ” button lights up).

Start engine.

Begin climate control self diagnosis Vehicle diagnosis, testing and information system VAS 5051 VAS 5051 , Vehicle self diagnosis

Select the function “Read measurement values block” and the indication group “012” Vehicle diagnosis, testing and information system VAS 5051 VAS 5051 , Vehicle self diagnosis

Check the indications in the fields:

The field “4” shows 0% (the compressor is deactivated)

The field “4” shows that the pressure in the refrigerant circuit, at the measured ambient temperature, is the same or higher than the value in the table.

Ambient temperatura in °CIndicated pressure (bar of absolute pressure)
154,7
205,6
256,6
307,6
358,8

Note

  • In absolute pressure 0 bar means a vacuum. The normal atmospheric temperature is, thus, about 1 bar of absolute pressure. In general, most manometer scales represent atmospheric pressure as 0 bar, meaning an absolute pressure of 1 bar (this can be recognized if there is a -1 on the scale).
  • The pressure in the refrigerant circuit depends on atmospheric temperature. Due to thermal radiation from the components (eg. the radiator for refrigerant liquid), with the engine service temperature, a slightly higher pressure than that specified for the corresponding ambient temperature will be indicated.
  • If the pressure indicated is less than indicated in the table:

Check the measured value of the high pressure sender for the air conditioning G65, “Electrical verification” VAS 5051 Climatronic self diagnostics.

If it does not detect any fault in the high pressure sender, this means that there is very little refrigerant in the circuit.

Open the “Central” aerators on the dashboard.

Select the operation mode “Auto” in the E87.

Select the temperature range “LO” with the E87.

Adjust the direction of the air in the E87 towards “Dashboard air outlets”.

Select the function “Read measured value block” and the indication group “008”.

Check the indications in the fields:

Indication field “4” a cycle proportion greater than 75% (the regulation valve N280 is activated; the compresser is activated)

Check the indications in the fields:

Indication field “4” a cycle proportion greater than 75 % (the regulation valve N280 is activated; the compresser is activated)

If you measure a current greater than 0.7 A (the current flows through the N280; the compressor is activated).

The pressure shown in the indication field “4” increases past this value when the compressor is deactivated.

Note

  • .
  • does not vary and the compressor is correctly energised (indication fields
    and
    of group 012), it means there is a fault in the refrigernat circuit. Send the vehicle to a workshop specialising in SEAT air conditioning.

Press the button for the air recirculation flap (the “air recirculation function” symbol on the button lights up).

Bring the engine speed up to 2,000 rpm (begin timing).

Select the function “Read measurement values block” Vehicle diagnosis, testing and information system VAS 5051 VAS 5051 , Vehicle self diagnosis ; indication group “007”.

Compare the value displayed in indication field 4 (corresponding to sender G263) with the values in the diagram.

E80-0060
A Air temperature measured by the evaporator outlet temperature sender G263 B Ambient temperature C Acceptable tolerance range

The air temperature measured should be within the specified tolerance range, according to the ambient temperature, after 5 minutes.

Note

  • and
    :

If the value in field “1” is lower than field “4” check the sender G263, verifying it is correctly fitted and that the electrical connections do not have contact resistances. if the sender is faulty, replace it.

If the measured value in field “1” is the same as field “4”, locate the fault if it differs from the theoretical value.

Compare the measured values indicated in fields “4” and “1” (corresponding to sender G263 and to sender G191). The measured value in field “1” (of the outlet temperature sender G191) may be a maximum of 3°C higher after 5 minutes.

If the measured value in field “1” is more than 3°C higher than the value in indication field “4”, locate the fault if the temperature increases after the evaporator.

  • dashboard vents can also be measured using Minitester SAT 4002, for example.
  • The air conditioning function is, eg. to detect due to the fact that the refrigerant pipe cools at the low pressure side (wide duct).
  • G191 is too high, locate the fault if the temperature increases after the evaporator.

Note

  • and in relatively high humidity) the pressure may reach 31 bar in virtue of the extremely high refrigeration performance involved in these cases.
  • At ambient temperatures below 25°C, the pressure in the refrigerant circuit does not usually exceed 16 bar (the refrigerant liquid fan operates at speed 1 and cools the condenser). So that the pressure can reach 16 bar, to activate speed 2 of the fan, you can briefly close the air inlets in the bonnet and bumper, for example.
  • E87 calculates the prevailing pressure in the refrigerant circuit.
  • E87 does not activate the compressor (the regulating valve is not energised N280). The compressor is only re-activated after the cycle proportion exceeds 12.5% (equivalent to 1.5 bar absolute pressure) or had dropped below 84% (equivalent to 29 bar absolute pressure).
  • E87 limits its performance:
  • As soon as the pressure in the refrigerant circuit exceeds 30 bar (absolute pressure) (maximum compressor performance will not be enabled until the pressure has dropped below 27 bar).
  • As soon as the refrigerant liquid temperature exceeds 115°C (at 118°C it is fully deactivated).
  • E87 only re-activates the compressor when the pressure has dropped below 29 bar (cycle proportion below 84%)

Parts & tools for this job For 2002 SEAT Ibiza

As an Amazon Associate we earn from qualifying purchases.