Workshop Manuals Factory service & repair SEAT
01 Technical data02 Self diagnosis, V.A.G Inspection Service03 Engine assy, cylinder block, crankcase04 Enginecrankshaft group, pistons05 Engine cylinder head, valve gear06 Engine lubrication07 Engine cooling08 Fuel supply, gas operation09 Fuel preparation system Diesel injection10 Mixture preparation system, electronic inj., Gas11 Exhaust system12 Starter-current supply-CC13 Ignition system, glow plug system14 Clutch, control15 Gearbox mechanics, operation, construction, diff.16 Gearbox, mechanics, gears, shafts, internal operation17 Final drive, differential, differential lock18 Front suspension, drive shafts19 Rear suspension, drive shaft20 Wheels, tyres. axle align21 ABS, ADR, TCS, EDL, ESP22 Brake, brake mechanics23 Brakes, hydraulics, regulator, servo24 Steering25 Body front26 Body centre, roof, frame27 Body, rear28 Bonnet, flaps, cab, central locking29 Front door, central locking30 Rear door, sliding door, wing doors, central locking31 Bumper32 Glazing/window mechanism33 Exterior equipment34 Interior equipment35 Passenger protection36 Trim, noise insulation37 Seat padding, covers38 Heating39 Air conditioner40 Instruments, GCI41 Infotainment42 Windscreen wipe/wash system43 Lights, lamps, switches outside44 Lights, lamps, switches inside, anti-theft system45 Wiring
SEAT Inca (1995-2003)39 · Air conditioner
39 · Heating & A/C

Connection plan for vacuum hoses

Make
SEAT
Model
Inca
Year
1995–2003
Section
Heating, air conditioning › Connection plan for vacuum hoses
Air conditionerConnection plan for vacuum hoses

Connection plan for vacuum hoses

Heating-ventilation-air conditioning system · Heating, air conditioning · Manually regulated air conditioning: repairing · Inca from 2000 · Edition 07.01

Note!

  • Depth of insertion for the vacuum hose in the vacuum reservoir: 30 mm, penetration depth for the depression hoses in the plastic hose: onto stop (15 mm approx.)
  • The vacuum is created in petrol engines by means of a suction pipe, and in diesel engines it is created by means of the vacuum pump
E87-0068
  • 1 Depressor for the fresh air and air recirculation flap
    In the heating and air conditioning system
  • 2 Flexible pipe
    Inside the vehicle
  • 3 Tube for vacuum line
    Assembly Fig. “Interior air conditioning and heating”
  • 4 Plastic hose
  • 5 Two way valve for the fresh air and air recirculation flap N63
    Installation and removal Fig. “Air conditioning and heating: engine bay” After the connection, check the depression hoses:
    With the created pressure and the existing vacuum, the depressor closes the flap
    When the pressure is not created or the vacuum existant, the depressor opens the flap
  • 6 Flexible pipe
  • 7 Distributor body
    Only for vehicles with petrol engine
  • 8 Tighten bolt
  • 9 Vacuum tank
    Only for vehicles with petrol engine
    Remove Fig. “Air conditioning and heating: engine bay”
  • 10 Return valve
    Arrow points in direction of suction
  • 11 To the admission tube or the vacuum pump
  • 12 To brake servo

Parts & tools for this job For 1995 SEAT Inca