Coolant agent circuit parts: repairing
- Make
- SEAT
- Model
- Inca
- Year
- 1995–2003
- Section
- Heating, air conditioning › Coolant agent circuit parts: repairing
‹ Prev Repairs to the coolant agent of the circuit, can only be done by qualified mechanics (Air conditioning Specialised OfficNext › Pressure sender G65: checking
Air conditionerCoolant agent circuit parts: repairing
Coolant agent circuit parts: repairing
Note!
- unit SAT 4006B
- V.A.G and SAT workshop equipment filing cabinet
- Chapter “Safety precautions when working on vehicles with air conditioning and how to procede with the coolant agent R134a”
- All the coolant agent circuit components that are open must be closed off with plugs in order to prevent moisture from entering
- The O-rings for the circuits of the coolant agent R134a are not distinguishable by color now. From now on only black and coloured rings will be used indistinctively
- Parts marked with an asterisk (*) can be replaced without opening or emptying the circuit

- 1 Evaporator
Inside the vehicle
Removal Chapter “Evaporator housing: dismantling and assembling”, Evaporator housing: dismantling and assembling - 2 Perforated plate
- 3 O-ring
10 mm; 1.8 mm - 4 Heat protection*
- 5 O-ring
7.6 mm; 1.8 mm - 6 Drain and fill valve
High pressure side
It is prohibited, by law, to release coolant agent into the athmosphere
Draining with service station SAT 4006B
Removal and installation Chapter “Evaporator housing: dismantling and assembling”
Capacities Chapter “Evaporator housing: dismantling and assembling” - 7 Coolant flexible hose
From the compressor to the condenser - 8 Combi bolt
22 Nm - 9 O-ring
20.5 mm; 1.8 mm - 10 Coolant flexible hose
From the compressor to the expansion valve - 11 Compressor
Identification: Sanden SD7-V16 designation - 12 Damper
- 13 Magnetic coupling N25 of the compressor
Manufacturer Sanden; SD7-V16
Magnetic coupling N25: repair Chapter “Magnetic coupling N25 : repair; Mark Sanden, type SD7-V16”
Magnetic coupling of the compressor: removing and installing Chapter “Magnetic coupling of the compressor: removing and installing” - 14 Pressure relief valve
No spare part
Check Fig. “Air conditioning and heating: engine bay” - 15 O-ring
20.5 mm; 1.8 mm - 16 O-ring
10.8 mm; 1.8 mm - 17 Thread 3/4" - 16 UNF
35 Nm - 18 Condenser
Removal and installation Chapter “Condenser: Removing and installing” - 19 Thread 5/8" - 18 UNF
15 Nm - 20 O-ring
7.6 mm; 1.8 mm - 21 Foam coating
- 22 Thread 3/4" -16 UNF
35 Nm - 23 O-ring
10.8 mm; 1.8 mm - 24 Pressure sender G65*
8 Nm
Substitute the O-gasket ( observe the spare part number)
Removal Fig. “Air conditioning and heating: engine bay”
Checking Chapter “Pressure sender G65 : checking” The high pressure sender may be replaced without having to extract the coolant agent of the refrigerant circuit The pressure sender G65 sends information to the coolant agent radiator fan control unit J293 and the motor control unit The pressure sender G65 cannot be checked by means of the engine control unit Check the air conditioning high pressure transmitter G65 Chapter “Pressure sender G65 : checking” Function:Disconnects the air conditioning if the pressure is too low (e.g. in the case of coolant agent leak) Changes the coolant agent radiator fan V7 to the next higher speed in case of pressure increase in the coolant agent circuit Disconnects the air conditioning if the pressure is too low (e.g. in the case of coolant agent leak) - 25 O-ring
7.6 mm; 1.8 mm - 26 Drier liquid tank
Functions Fig. “Coolant agent circuit parts: repairing” - 27 O-ring
10.8 mm; 1.8 mm - 28 Thread 5/8" - 18 UNF
15 Nm - 29 Coolant agent hose
- 30 Allen bolt with washer
7 Nm - 31 Suction and filling valve
Low pressure side
It is prohibited, by law, to release coolant agent into the athmosphere
Draining with service station SAT 4006B
Removal and installation Fig. “Coolant agent circuit parts: repairing”
Capacities Chapter “Capacities” - 32 O-ring
16.7 mm; 1.8 mm - 33 Allen head bolt
8 Nm - 34 Expansion valve
The cooling of the evaporator is preadjusted
Expansion valve is installed with an isolator
Remove Chapter “Expansion valve: removal” Functions The expansion valve sprays the coolant agent as it arrives and regulates the flow rate so that steam turns into gas at the exit of the evaporator, depending on the heat delivery The expansion valves for the coolant agent R134a circuit have a green sticker in order to distinguish them - 35 O-ring
14 mm; 1.8 mm

First remove the coolant agent of the circuit with the unit SAT 4006B and, then, renew the valve (3).
Note!
- It is prohibited, by law, to release coolant agent into the athmosphere
- All the coolant agent circuit components that are open must be closed off with plugs in order to prevent moisture from entering

Remove first the coolant agent of the circuit with the unit SAT 4006B and then renew the valve (3).
Note!
- It is prohibited, by law, to release coolant agent into the athmosphere
- All the coolant agent circuit components that are open must be closed off with plugs in order to prevent moisture from entering

The tank picks up the liquid drops and uninterruptedly conveys them towards the expansion valve. The moisture which enters the coolant agent circuit, during assembly, is filtered in the tank through a drier.
Note!
- The fluid tanks have a green sticker, because the drier installed in them works only with coolant agent R134a
- Every time the coolant agent circuit is opened the drier liquid tank must renewed
‹ Prev Repairs to the coolant agent of the circuit, can only be done by qualified mechanics (Air conditioning Specialised OfficNext › Pressure sender G65: checking
Parts & tools for this job For 1995 SEAT Inca
- FLUIDCoolantSearch: SEAT coolant antifreeze
- PARTThermostatSearch: SEAT Inca 1995 thermostat
- TOOLCooling system pressure testerSearch: cooling system pressure tester
As an Amazon Associate we earn from qualifying purchases.