Workshop Manuals Factory service & repair SEAT
01 Technical data02 Self diagnosis, V.A.G Inspection Service03 Engine assy, cylinder block, crankcase04 Enginecrankshaft group, pistons05 Engine cylinder head, valve gear06 Engine lubrication07 Engine cooling08 Fuel supply, gas operation09 Fuel preparation system Diesel injection10 Mixture preparation system, electronic inj., Gas11 Exhaust system12 Starter-current supply-CC13 Ignition system, glow plug system14 Clutch, control15 Gearbox mechanics, operation, construction, diff.16 Gearbox, mechanics, gears, shafts, internal operation17 Final drive, differential, differential lock18 Front suspension, drive shafts19 Rear suspension, drive shaft20 Wheels, tyres. axle align21 ABS, ADR, TCS, EDL, ESP22 Brake, brake mechanics23 Brakes, hydraulics, regulator, servo24 Steering25 Body front26 Body centre, roof, frame27 Body, rear28 Bonnet, flaps, cab, central locking29 Front door, central locking30 Rear door, sliding door, wing doors, central locking31 Bumper32 Glazing/window mechanism33 Exterior equipment34 Interior equipment35 Passenger protection36 Trim, noise insulation37 Seat padding, covers38 Heating39 Air conditioner40 Instruments, GCI41 Infotainment42 Windscreen wipe/wash system43 Lights, lamps, switches outside44 Lights, lamps, switches inside, anti-theft system45 Wiring
SEAT Inca (1995-2003)39 · Air conditioner
39 · Heating & A/C

Coolant agent circuit parts: repairing

Make
SEAT
Model
Inca
Year
1995–2003
Section
Heating, air conditioning › Coolant agent circuit parts: repairing
Air conditionerCoolant agent circuit parts: repairing

Coolant agent circuit parts: repairing

Heating-ventilation-air conditioning system · Heating, air conditioning · Repairs to the coolant agent of the circuit, can only be done by qualified mechanics (Air conditioning Specialised Official Garages) · Inca from 2000 · Edition 07.01

Note!

E87-0070
  • 1 Evaporator
    Inside the vehicle
    Removal Chapter “Evaporator housing: dismantling and assembling”, Evaporator housing: dismantling and assembling
  • 2 Perforated plate
  • 3 O-ring
    10 mm; 1.8 mm
  • 4 Heat protection*
  • 5 O-ring
    7.6 mm; 1.8 mm
  • 6 Drain and fill valve
    High pressure side
    It is prohibited, by law, to release coolant agent into the athmosphere
    Draining with service station SAT 4006B
    Removal and installation Chapter “Evaporator housing: dismantling and assembling”
    Capacities Chapter “Evaporator housing: dismantling and assembling”
  • 7 Coolant flexible hose
    From the compressor to the condenser
  • 8 Combi bolt
    22 Nm
  • 9 O-ring
    20.5 mm; 1.8 mm
  • 10 Coolant flexible hose
    From the compressor to the expansion valve
  • 11 Compressor
    Identification: Sanden SD7-V16 designation
  • 12 Damper
  • 13 Magnetic coupling N25 of the compressor
    Manufacturer Sanden; SD7-V16
    Magnetic coupling N25: repair Chapter “Magnetic coupling N25 : repair; Mark Sanden, type SD7-V16”
    Magnetic coupling of the compressor: removing and installing Chapter “Magnetic coupling of the compressor: removing and installing”
  • 14 Pressure relief valve
    No spare part
    Check Fig. “Air conditioning and heating: engine bay”
  • 15 O-ring
    20.5 mm; 1.8 mm
  • 16 O-ring
    10.8 mm; 1.8 mm
  • 17 Thread 3/4" - 16 UNF
    35 Nm
  • 18 Condenser
    Removal and installation Chapter “Condenser: Removing and installing”
  • 19 Thread 5/8" - 18 UNF
    15 Nm
  • 20 O-ring
    7.6 mm; 1.8 mm
  • 21 Foam coating
  • 22 Thread 3/4" -16 UNF
    35 Nm
  • 23 O-ring
    10.8 mm; 1.8 mm
  • 24 Pressure sender G65*
    8 Nm
    Substitute the O-gasket ( observe the spare part number)
    Removal Fig. “Air conditioning and heating: engine bay”
    Checking Chapter “Pressure sender G65 : checking” The high pressure sender may be replaced without having to extract the coolant agent of the refrigerant circuit The pressure sender G65 sends information to the coolant agent radiator fan control unit J293 and the motor control unit The pressure sender G65 cannot be checked by means of the engine control unit Check the air conditioning high pressure transmitter G65 Chapter “Pressure sender G65 : checking” Function:Disconnects the air conditioning if the pressure is too low (e.g. in the case of coolant agent leak) Changes the coolant agent radiator fan V7 to the next higher speed in case of pressure increase in the coolant agent circuit Disconnects the air conditioning if the pressure is too low (e.g. in the case of coolant agent leak)
  • 25 O-ring
    7.6 mm; 1.8 mm
  • 26 Drier liquid tank
    Functions Fig. “Coolant agent circuit parts: repairing”
  • 27 O-ring
    10.8 mm; 1.8 mm
  • 28 Thread 5/8" - 18 UNF
    15 Nm
  • 29 Coolant agent hose
  • 30 Allen bolt with washer
    7 Nm
  • 31 Suction and filling valve
    Low pressure side
    It is prohibited, by law, to release coolant agent into the athmosphere
    Draining with service station SAT 4006B
    Removal and installation Fig. “Coolant agent circuit parts: repairing”
    Capacities Chapter “Capacities”
  • 32 O-ring
    16.7 mm; 1.8 mm
  • 33 Allen head bolt
    8 Nm
  • 34 Expansion valve
    The cooling of the evaporator is preadjusted
    Expansion valve is installed with an isolator
    Remove Chapter “Expansion valve: removal” Functions The expansion valve sprays the coolant agent as it arrives and regulates the flow rate so that steam turns into gas at the exit of the evaporator, depending on the heat delivery The expansion valves for the coolant agent R134a circuit have a green sticker in order to distinguish them
  • 35 O-ring
    14 mm; 1.8 mm
Low pressure drain and fill valve: removal and installation
V87-1434

First remove the coolant agent of the circuit with the unit SAT 4006B and, then, renew the valve (3).

Note!

  • It is prohibited, by law, to release coolant agent into the athmosphere
  • All the coolant agent circuit components that are open must be closed off with plugs in order to prevent moisture from entering
1 External threaded socket and slot for the O-ring 2 O-ring: 7.6 mm; 1.8 mm 3 Drain and fill valve 4 O-ring: 7.6 mm; 1.8 mm 5 CapLow pressure drain and fill valve: removal and installation
V87-1435

Remove first the coolant agent of the circuit with the unit SAT 4006B and then renew the valve (3).

Note!

  • It is prohibited, by law, to release coolant agent into the athmosphere
  • All the coolant agent circuit components that are open must be closed off with plugs in order to prevent moisture from entering
1 Inner threaded casing 2 O-ring: 10.8 mm; 1.8 mm 3 Drain and fill valve with slot and interior thread for the cap 4 O-ring: 10.8 mm; 1.8 mm 5 CapFunctions of the drier liquid tank
N87-0405

The tank picks up the liquid drops and uninterruptedly conveys them towards the expansion valve. The moisture which enters the coolant agent circuit, during assembly, is filtered in the tank through a drier.

Note!

  • The fluid tanks have a green sticker, because the drier installed in them works only with coolant agent R134a
  • Every time the coolant agent circuit is opened the drier liquid tank must renewed

Parts & tools for this job For 1995 SEAT Inca