Oil distribution
- Make
- SEAT
- Model
- Inca
- Year
- 1995–2003
- Section
- Heating, air conditioning › Oil distribution
Air conditionerOil distribution
Oil distribution
In the refrigerant circuit the oil in the oil compressor tray is distributed, before the first start of air conditioning. The distribution in the refrigerating circuit with an evaporator is:
| Compressor | 50% approx. |
| Condenser | 10% approx. |
| Intake flexible hose | 10% approx. |
| Evaporator | 20% approx. |
| Drier liquid tank | 10% approx. |
Note!
- Due to its chemical properties, the refrigerant circuit oil should not be eliminated together with the engine oil or lubricating oils.
Parts & tools for this job For 1995 SEAT Inca
- PARTOil filterSearch: SEAT Inca 1995 oil filter
- TOOLOil filter wrenchSearch: oil filter wrench
- FLUIDEngine oilSearch: SEAT Inca engine oil