Connecting A/C service station for measuring and checking |
–
| Connect the A/C service station to the power supply. |
–
| Connect quick-release connector adapters to filler hoses for A/C service station (handwheels not turned inwards, i.e. manual stop valves not open). |
–
| Switch on A/C service station and evacuate filler hoses (necessary only if there is air in the filler hoses). |
–
| Switch off A/C service station. |
–
| Unscrew sealing caps from service connections (with valve). |
–
| Connect service station via service connections to the vehicle refrigerant circuit using quick-release connector adapter. |
–
| Turn handwheel of quick-release connector adapter inwards only far enough to ensure that valves on service connections are open (check using a manometer; do not overstress valves). |
–
| Perform the intended measuring and checking work. |
|
|
|