seat Workshop Repair Guides

SEAT Workshop Service and Repair Manuals

General notes on air conditioning systems > < Renewing components
Detecting leaks in refrigerant circuit using leak detecting systemVAS 6196 or leak detecting systemVAS 6201.
Detecting leaks in refrigerant circuit using leak detecting system -VAS 6196- or leak detecting system -VAS 6201-.
   
Leak detecting system -VAS 6196-
or
  W00-10195
Leak detecting system -VAS 6201-
  Note!
Small leaks can be made visible, for example, by using a fluorescent leak detection additive -VAS 6196/1-.
Leak detection:
–  If the refrigerant circuit is completely empty, charge with about 100 grams of refrigerant.
–  Introduce leak detection additive -VAS 6196/1- into refrigerant circuit and use a UV lamp to examine refrigerant circuit.
  Note!
The leak detection additive can be allowed to remain in the refrigerant circuit.
  A87-0504

General notes on air conditioning systems > < Renewing components