| Connect manual vacuum pump -SAT 1390- to the valve's connection -A-. |
–
| Create pression, there must be an air path. |
–
| Create vacuum, vacuum should be maintained. |
–
| Connect manual vacuum pump -SAT 1390- to the valve's connection -B-. |
–
| Create pression, there must be an air path. |
–
| Create vacuum, vacuum should not be maintained. |
If the test results are not as indicated, replace the safety valve. |
|
|
|