| Connect tester -VAG 1598/31- to control unit cable harness, and engine control unit. |
–
| Link connector in the charge pressure sender -G31-. |
–
| Connect multimeter to measure voltage at sockets “101” and “108”. |
–
| Start the engine and measure the voltage. |
Specification: 1,80 ... 2.00 V . |
–
| From time to time, accelerate the engine until speed increases. |
Specification: 2,00 ... 3.00 V . |
If the specification is not obtained: |
–
| Replace the Charge pressure sender -G31-. |
|
|
|