| Connect hand vacuum pump -VAS 6213- to activated charcoal filter solenoid valve 1 -N80-. |
–
| Connect contacts of the solenoid valve -1- to the battery using test leads. This will open activated charcoal filter solenoid valve 1 -N80-. |
Then immediately operate hand vacuum pump -VAS 6213- several times. |
l
| A vacuum must build up. |
–
| Again disconnect battery to cut off current supply. |
If a vacuum does not build up: |
–
| Replace double non-return valve -1-. |
Dual non-return valve, activated charcoal filter solenoid valve 1 -N80- and plastic hoses are combined as one unit. The vacuum pipe must be dismantled for replacing. |
|
|
|