Cleaning evaporator
- Make
- SEAT
- Model
- Leon León
- Year
- 5F, 2012–2020
- Section
- Heating, air conditioning › Cleaning evaporator
Cleaning evaporator
- Ultrasonic cleaning unit for the air conditioner circuit VAS 6189B
- Cleaning liquid VAS 6189/1
- Suction nozzle VAS 6288
- Commercially available dust extractor
By switching from fresh air to air recirculation mode, check whether the air conditioning unit evaporator is really the source of the odour
Check and if necessary clean the plenum chamber water drain Chapter “Checking and cleaning plenum chamber water drain”.
Remove dust and pollen filter Chapter “Removing and installing dust and pollen filter”.
Clean the mounting slot for the dust and pollen filter.
Seal the opening for the dust and pollen filter at the air conditioning unit.
Start the engine.
Close the windows, sun roof and rear lid.
Open all dash panel vents.

Make the following settings on the operating unit, air conditioning system control unit J301:
- AC button (5) does not light up.
- (1) to the stop.
- recirculated-air mode(2) button: the lamp of the button lights up.
- (3) to speed .
- (4) to .

Make the following settings on the operating unit, Climatronic control unit J255:
- AC button (11) does not light up.
- (1, 7) to : Display for driver's and front passenger's side in display (3) of the J255.
- (5, 6) for .
- (9) for the fresh air blower to the lowest level: The V2 runs with the lowest speed.
Shake the bottle with the cleaning fluid VAS 6189/1 and insert into the ultrasonic cleaning unit for the air conditioner circuit VAS 6189B.
Note
- Operating instructions of VAS 6189B.
Connect the ultrasonic cleaning unit for the air-conditioning circuit VAS 6189B to the footwell vent on the front-passenger side Air-conditioning system - with refrigerant R134a Rep. gr.00, “For technical reasons, it is currently not possible to generate an automatic link to this workshop manual. Manually select the workshop manual in ELSA”.
Start up the ultrasonic air conditioner cleaning unit VAS 6189B (see operating instructions of the unit) and position the outlet hose such that the vapour emerging is drawn in by the fresh air blower V2 via the recirculated-air opening of the air conditioner unit (in the passenger's footwell behind the glove compartment).
Close the vehicle doors.
Note
- ultrasonic cleaning unit for the air conditioner circuit VAS 6189B, the process is completed.
Switch off the ultrasonic air conditioner cleaning unit VAS 6189B.
Open the vehicle doors and vent the vehicle for at least 10 minutes.
Remove the ultrasonic cleaning unit for the air conditioner circuit VAS 6189B from inside the vehicle and clean it.
Switch ignition OFF.
Install dust and pollen filter Chapter “Removing and installing dust and pollen filter”.
Parts & tools for this job For 2012 SEAT Leon
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: SEAT Leon 2012 cabin filter