Removing and installing air conditioner compressor
- Make
- SEAT
- Model
- Leon León
- Year
- 5F, 2012–2020
- Section
- Heating, air conditioning › Removing and installing air conditioner compressor
Removing and installing air conditioner compressor
- Torque wrench V.A.G 1331/ (5 … 50 Nm)

- Air conditioner service station VAS 6007A or later model.

Note
- The refrigerant circuit must be purged with refrigerant R134a under the following circumstances:
- If dirt or other contamination is in the circuit.
- If during the evacuation of a leak-tight refrigerant circuit the vacuum is not maintained at the gauge (there is moisture in the refrigerant circuit and this generates vapour pressure).
- If the refrigerant circuit has been left open for longer than normally required for repairs (e.g. following an accident).
- When pressure and temperature measurements in the refrigerant circuit indicate that there is moisture in the refrigerant circuit.
- There is doubt about the amount of refrigerant oil in the refrigerant circuit.
- The air conditioner compressor has to be exchanged because of internal damage (e.g. noisy or lack of power).
The procedure for purging with refrigerant R134a is described in ELSA under Clearing refrigerant circuit of contaminants; Purging (cleaning) refrigerant circuit with refrigerant R134a.
Notes on repair work to vehicles with air conditioning system and on handling refrigerant can be found in ELSA under Air conditioning system with refrigerant R134a Rep. gr. 00.
Notes on testers and tools for repair work to vehicles with air conditioning can be found in ELSA under Testers and tools.
Observe notes Anchor “Removing and installing air conditioner compressor”.
Remove front bumper Front bumper; Removing and installing front bumper.
Remove poly V-belt Cylinder block (pulley end); Removing and installing poly V-belt.
Disconnect connector (2) from air conditioner compressor (1).
Extract refrigerant, e.g. with air conditioner service station VAS 6007A before opening refrigerant circuit.

Warning
Danger from refrigerant escaping under pressure!
Freezing of skin and other body parts.
- Evacuate the refrigerant and then open the refrigerant circuit immediately.
- If more than 10 minutes have elapsed since evacuation and the coolant circuit has not been opened, evacuate the refrigerant again. Pressure builds up in the coolant circuit as a result of secondary evaporation.
Remove bolts (4) (23 Nm).
Disconnect refrigerant lines (3) and (6) from air conditioner compressor (1).
Note
- (4) of refrigerant lines (3) can be accessed through the maintenance opening in the lock carrier.
Remove securing bolts (5) and remove air conditioner compressor.
Installation is carried out in the reverse order; noting the following in the process:

Note
- (6) are properly seated.
- The assembly is carried out in reverse order. However, observe the following:
- Anchor “Removing and installing air conditioner compressor”.
- must be carried out Anchor “Removing and installing air conditioner compressor”.
Only start engine after refrigerant circuit has been assembled.
After installing a new air conditioner compressor or filling with fresh refrigeration oil (e.g. after purging refrigerant circuit), turn cover cap compressor 10 revolutions by hand before starting engine. This will prevent damage to the air conditioner compressor.
Only start the engine after the refrigerant circuit has been filled.
Note
- air conditioning system magnetic clutch N25.
- air conditioning system magnetic clutch N25 only starts if it receives a signal from the high-pressure sender G65 to avoid damage to the compressor when refrigerant circuit is empty.
Note
- When starting the engine for the first time after filling the refrigerant circuit, take note of the following:
Start engine with air conditioner compressor switched off (control lamp in AC button is off) and wait until idling speed is stable.
Open the dash panel vents.
Fresh air blower V2 at least set to 3rd speed.
Set temperature to “Cold” on control and display unit for air conditioning system.
Switch on air conditioner compressor (control lamp in AC button lights up) and let it run for at least 5 minutes with engine at idling speed.
Note
- must be carried out Anchor “Removing and installing air conditioner compressor”.
- Compressor filled with refrigerant filled at pressure end
- Engine off
- .
- AC button off)
Start the engine.
Wait approx. 5 seconds until idling has stabilised.
Switch on air conditioning system (warning lamp in AC button on).
Allow engine to idle for 2 minutes.
Switch off engine.
Parts & tools for this job For 2012 SEAT Leon
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: SEAT Leon 2012 cabin filter