Skoda Workshop Service and Repair Manuals
HOME
FEATURES
MENU
INDEX
ABOUT US
Replacing the valve guides >
< Removing and installing camshaft
Octavia Mk1
Drive unit
1.6 ltr./55 kW Engine - Mechanical Components
Engine cylinder head, valve gear
Repairing Valve Gear
Inspect valve guides
Inspect valve guides
Inspect valve guides
Special tools and workshop equipment required
t
Universal dial gauge holder -MP 3-447-
t
Dial gauge
Procedure
–
Place the cylinder head on level metal plate.
–
Insert new valve into guide. End of valve stem must be flush with guide.
–
Determine valve rock.
Wear limit:
Inlet valve guide = 1.0 mm
Outlet valve guide = 1.3 mm