Readout on -V.A.G 1552- | Possible cause of fault | Rectifying fault |
No fault detected | | If after repair “No fault detected” is displayed, the self-diagnosis is completed. If the Haldex coupling does not operate without fault in spite of display read-out “No fault detected”, proceed as follows: 1. Perform a test drive at a speed above 20 km/h. 2. Interrogate the fault memory again, if still “No fault detected” is stored. 3. Run through the Electrical Test completely → Chapter. |
00453 | | | |
Function restriction due to overtemperature. | | t
| mechanical fault of the Haldex coupling |
| –
| Reading measured value block → Chapter, display group number 002. |
–
| Electrical test → Chapter, perform test step 5. |
|
00526 | | | |
Brake light switch -F- implausible signal | t
| Line interruption or short-circuit to earth or positive between control unit -J492- and brake light switch -F- |
t
| Brake light switch -F- defective |
| –
| Test wiring and plug connections according to current flow diagram. |
–
| Read measured value block → Chapter, display group number 001. |
|
00532 | | | |
Supply voltage signal too low | | t
| Open circuit in wiring or short circuit to earth or to positive |
| –
| Reading measured value block → Chapter, display group number 002. |
–
| Test wiring and plug connections according to current flow diagram. |
|
| | | |
| | | |
00532 | | | |
Supply voltage signal too high | | t
| Voltage regulator -C1- on generator defective |
| –
| Reading measured value block → Chapter, display group number 002. |
|
01043 | | | |
Control unit wrong software version | | t
| wrong control unit fitted |
| |
01155 | | | |
Clutch mechanical fault | | t
| mechanical fault of the Haldex coupling |
| –
| Electrical test → Chapter, perform test step 5. |
|
01312 | | | |
Databus drive defective | t
| Fault in databus wiring |
t
| self-diagnostic control unit defective |
| –
| Read measured value block → Chapter, display group number 125. |
–
| Electrical test → Chapter, perform test step 4. |
–
| Read fault memory of all control units connected to the data BUS and if necessary eliminate fault. |
|
01314 | | | |
Engine control unit no communication | | t
| Fault in databus wiring |
t
| incorrect or defective engine control unit |
| –
| Read measured value block → Chapter, display group number 125. |
–
| Electrical test → Chapter, perform test step 4. |
|
01314 | | | |
Interrogate fault memory of engine control unit
| | t
| Fault entry in 4AV control unit |
| |
01316 | | | |
Brake control unit no communication | | t
| Fault in databus wiring |
t
| wrong or defective control unit -J104- |
| –
| Read measured value block → Chapter, display group number 125. |
–
| Electrical test → Chapter, perform test step 4. |
–
| Interrogate the fault memory of the engine control unit -J104- and eliminate possible faults → Chassis → Rep. Gr.45. |
|
065535 | | | |
Control unit defective | | t
| Four-wheel drive control unit -J492- defective |
| |