Removing the dash panel Body Work Rep. gr. 70.
Remove left footwell vent.
Remove data bus diagnostic interface control unit J533 Electrical System Rep. gr. 97.
Unscrew screws (3) and nuts (1) (10 Nm) and remove the support (2).

Unplug connector (C).

Unscrew screws (A) and remove control motor (B).
Slacken the lever (E) from the coupling rod (D).
Installation is performed in the reverse order, pay attention to the following points:
Note
- After installing the control motor, it is necessary to test the operation of the defroster flap.
- with the Vehicle diagnostic tester.