Left-hand drive
- Make
- Skoda
- Model
- Superb II
- Year
- 3T, 2008 on
- Section
- Heating, Air conditioning › Left-hand drive
Left-hand drive
Switch off the ignition and all electrical components.
Remove the footwell vent on the driver's side Chapter “Remove and install footwell vent”.
Remove data bus diagnostic interface control unit J533 Electrical System Rep. gr. 97.
Release screws ( 3 ) (10 Nm).

The screws (1) are not released.
Press the bracket (1) in the direction of the brake pedal (arrow) and fasten it there with the cable strap.

Mark the connector (C) (the design is identical to other connectors, danger of mix-ups) and subsequently remove it at the left temperature flap control motor V158 (B).

Removing cover (A).
Release the fixing screws (D) (1.4 Nm) and remove the control motor (B).
Slacken the lever (E) of the control motor from the coupling rod (F).
Installation is performed in the reverse order, pay attention to the following points:
Note
- After installing the control motor, it is necessary to test the operation of the left temperature flap.
- with the Vehicle diagnostic tester.
Parts & tools for this job For 2008 Skoda Superb
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Skoda Superb 2008 cabin filter