01 Technical Data02 Self diagnosis, V.A.G Inspection Service03 Engine assy, cylinder block, crankcase04 Enginecrankshaft group, pistons05 Engine cylinder head, valve gear06 Engine lubrication07 Engine cooling08 Fuel supply, gas operation09 Exhaust turbocharger, G-charger10 Fuel preparation system Diesel injection11 Mixture preparation system, electronic inj., Gas12 Exhaust system13 Starter-current supply-CC14 Ignition system, glow plug system15 Clutch, control16 Torque converter17 Gearbox mechanics, operation, construction, diff.18 Gearbox, mechanics, gears, shafts, internal operation19 Automatic gearbox, control, assembly, housing20 Automatic gearbox, gears, control21 Final drive, differential, differential lock22 Front suspension, drive shafts23 Rear suspension, drive shaft24 Wheels, tyres. axle align25 ABS, ADR, TCS, EDL, ESP26 Brake, brake mechanics27 Brakes, hydraulics, regulator, servo28 Steering29 Body front30 Body centre, roof, frame31 Body, rear32 Sliding roof33 Exterior equipment34 Seat frames35 Aux. heater/heater booster36 Air conditioner37 Instruments, GCI38 Infotainment39 Windscreen wipe/wash system40 Lights, lamps, switches outside41 Lights, lamps, switches inside, anti-theft system42 Wiring
Skoda Superb II (3T, 2008 on)36 · Air conditioner
36 · Heating & A/C

Summary of components

Make
Skoda
Model
Superb II
Year
3T, 2008 on
Section
Heating, Air conditioning › Summary of components
Air conditionerSummary of components

Summary of components

Heating, ventilation, air conditioning system · Heating, Air conditioning · Repairing the air conditioning system - engine compartment · Superb II, Superb II from 2008 · Edition 01.2012

S87-0304
  • Fluid container with dessicator / dessicator cartridge*
    removing and installing Chapter “Removing and installing fluid reservoir with dessicator / dessicator cartridge”
    Replace fluid container with dessicator / dessicator cartridge, if... Chapter “Replacing dessicator cartridge / fluid reservoir with dessicator”
  • Regulating valve for compressor of air conditioning system N280*
    Elements of the AC compressor, do not replace individually Note Depending on the required cooling output the regulating valve receives a PWM signal (500 Hz) from the air conditioning control unit J301 or from the Climatronic control unit J255 and regulates the displacement of the AC compressor via the suction pressure/position of the articulated disc.
  • AC compressor*
    various manufacturers: Chapter “Refrigerant R134a”; Contents
    Removing and installing the refrigerant lines Chapter “Remove refrigerant lines from the AC compressor”
    Belt protection for blocked AC compressor Chapter “Parts for securing the refrigerant circuit”
    Removing and installing AC compressor Chapter “Removing and installing AC compressor”
    Running-in instruction Chapter “Running-in instructions of the AC compressor”
  • Condenser*
    Removing and installing the refrigerant lines Chapter “Remove the refrigerant lines from the condenser”
    Removing and installing the condenser Chapter “Removing and installing the condenser”
  • High-pressure sender G65
    function Chapter “Parts for securing the refrigerant circuit”
    remove and install, test Chapter “Removing and installing, inspecting high pressure senderG65”
    inspect Vehicle diagnostic tester in the function „Targeted fault finding“
  • Pressure relief valve*
    Replace O-ring (Electronic Catalogue of Original Parts).
    Tightening torque: 10 Nm
    function Chapter “Parts for securing the refrigerant circuit”
    check Chapter “Inspecting the pressure relief valve on the AC compressor”
  • Extractor and filling valve*
    High-pressure side
    for exhausting, filling and measuring
    Contents Chapter “Refrigerant R134a”
    always screw on cap with gasket
    Description, removing and installing Chapter “Extractor, filler and measurement valves for quick couplings of the AC service station on the refrigerant circuit”
  • Clamp
  • Retaining clip
  • Exhaust valve*
    Low-pressure side
    for exhaust and measurement only
    always screw on cap with gasket
  • Expansion valve*
    removing and installing Chapter “Removing and installing the expansion valve”
  • Holder for refrigerant lines
  • 20 Nm