Summary of components
- Make
- Skoda
- Model
- Superb II
- Year
- 3T, 2008 on
- Section
- Heating, Air conditioning › Summary of components
‹ Prev Repairing the air conditioning system - engine compartmentNext › Remove the refrigerant lines from the condenser
Air conditionerSummary of components
Summary of components

- Fluid container with dessicator / dessicator cartridge*
removing and installing Chapter “Removing and installing fluid reservoir with dessicator / dessicator cartridge”
Replace fluid container with dessicator / dessicator cartridge, if... Chapter “Replacing dessicator cartridge / fluid reservoir with dessicator” - Regulating valve for compressor of air conditioning system N280*
Elements of the AC compressor, do not replace individually Note Depending on the required cooling output the regulating valve receives a PWM signal (500 Hz) from the air conditioning control unit J301 or from the Climatronic control unit J255 and regulates the displacement of the AC compressor via the suction pressure/position of the articulated disc. - AC compressor*
various manufacturers: Chapter “Refrigerant R134a”; Contents
Removing and installing the refrigerant lines Chapter “Remove refrigerant lines from the AC compressor”
Belt protection for blocked AC compressor Chapter “Parts for securing the refrigerant circuit”
Removing and installing AC compressor Chapter “Removing and installing AC compressor”
Running-in instruction Chapter “Running-in instructions of the AC compressor” - Condenser*
Removing and installing the refrigerant lines Chapter “Remove the refrigerant lines from the condenser”
Removing and installing the condenser Chapter “Removing and installing the condenser” - High-pressure sender G65
function Chapter “Parts for securing the refrigerant circuit”
remove and install, test Chapter “Removing and installing, inspecting high pressure senderG65”
inspect Vehicle diagnostic tester in the function „Targeted fault finding“ - Pressure relief valve*
Replace O-ring (Electronic Catalogue of Original Parts).
Tightening torque: 10 Nm
function Chapter “Parts for securing the refrigerant circuit”
check Chapter “Inspecting the pressure relief valve on the AC compressor” - Extractor and filling valve*
High-pressure side
for exhausting, filling and measuring
Contents Chapter “Refrigerant R134a”
always screw on cap with gasket
Description, removing and installing Chapter “Extractor, filler and measurement valves for quick couplings of the AC service station on the refrigerant circuit” - Clamp
- Retaining clip
- Exhaust valve*
Low-pressure side
for exhaust and measurement only
always screw on cap with gasket - Expansion valve*
removing and installing Chapter “Removing and installing the expansion valve” - Holder for refrigerant lines
- 20 Nm
‹ Prev Repairing the air conditioning system - engine compartmentNext › Remove the refrigerant lines from the condenser
Parts & tools for this job For 2008 Skoda Superb
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Skoda Superb 2008 cabin filter
As an Amazon Associate we earn from qualifying purchases.