Structure of the refrigerant circuit
   
Structure of the refrigerant circuit
  Note
All air conditioning components marked * as well as all refrigerant hoses and refrigerant lines must be repaired or replaced in service centres, as the refrigerant must first be drained off at a service position.
HP = High-pressure side
LP = Low-pressure side
1 - Compressor*
2 - Air conditioning system magnetic coupling -N25-
3 - Oil drain plug*
4 - Pressure relief valve*
5 - Connection with valve*
6 - Air conditioner pressure switch -F129-
7 - Condenser*
8 - Screwed connection in the refrigerant line*
9 - Cap
10 - Extractor and filling valve*
q   High-pressure side
11 - Throttle*
12 - Evaporator*
13 - Extractor and filling valve*
q   Low-pressure side
14 - Cap
15 - Catch pan*

   