Contact assignment of multipin plug connections on the rear side of the control for heating and air conditioning system |
3 - | Middle vent temperature sender -G191- (no longer applicable as of CW 46.2010) |
5 - | High-pressure sender -G65- |
7 - | CAN bus Low (comfort) |
8 - | CAN bus High (comfort) |
12 - | Right seat heating (optional) |
13 - | Left seat heating (optional) |
15 - | Terminal 75 seat heating (optional) |
16 - | Regulating valve for compressor of air conditioning system -N280- |
18 - | Middle vent temperature sender -G191- (no longer applicable as of CW 46.2010) |
1 - | Control motor for temperature flap -V68- |
2 - | Evaporator vent temperature sender -G263- |
3 - | Potentiometer for front air distribution control motor -G470- |
4 - | Footwell vent temperature sender -G192- (no longer applicable as of CW 46.2010) |
5 - | Potentiometer for temperature flap control motor -G92- |
7 - | + 5 V for potentiometer for front air distribution control motor -G470- |
9 - | Re-circulating air flap control motor -V113- |
10 - | Re-circulating air flap control motor -V113- |
11 - | Control motor for temperature flap -V68- |
12 - | Positioning motor of front air distribution -V145- |
13 - | Positioning motor of front air distribution -V145- |
|
|
|