a. Temporarily install generator with bolts A and B.
b. Adjust the V belt No. 1 tension by tightening bolt C.
c. Tighten bolts A and B.

Torque: 58 N.m (592 kgf.cm, 43 ft.lbf) for bolt A

18 N.m (184 kgf.cm, 13 ft.lbf) for bolt B

d. Install the generator wire with the nut.

Torque: 9.8 N.m (100 kgf.cm, 7 ft.lbf) 

e. Connect the generator connector.
f.

Install the wire harness clamp.

2. INSPECT DRIVE BELT