Test
|
Work Order Description
|
Nominal Value
|
T001
|
Check: Interruption of Voltage Supply Circuit
|
- Ignition OFF
- All consumers turned off
- Disconnect wiring harness connector from:
A1_S22A Control Unit - Selector Lever (Wiring Harness Connector XC79 ) & Diagnostic tester
- Ignition ON
- Measure voltage between the following terminals:
A1_S22A Control Unit - Selector Lever Wiring harness connector (wiring harness side) terminal 2 (XC79) & Ground
|
greater than 11 V
|
|
|
T002
|
Check: Interruption of Voltage Supply Circuit
|
- Measure voltage between the following terminals:
A1_S22A Control Unit - Selector Lever Wiring harness connector (wiring harness side) terminal 2 (XC79) & A1_S22A Control Unit - Selector Lever Wiring harness connector (wiring harness side) terminal 3 (XC79)
|
greater than 11 V
|
|
|