Test conditions: proper charge state and ground connection of battery.  

Object Number: 616196  Size: DEFAULT  Inspect   

Check starter cable: proper connection to starter and positive battery terminal, the highest permissible voltage drop in the cable during the starting operation is 0.5 volt - measure voltage at starter terminal "50". For greater voltage drops: check contact part of ignition lock, selector lever switch and plug connections for adequate contact.  

Check starter: connect Opel Tester - proceed according to operating instructions.  

Notice: 

A short-circuit test must not be carried out because there is a risk of causing initial damage to the commutator.  

 

 