Checking specific gravity
- Make
- Volkswagen
- Model
- Caddy Mk3
- Year
- 2004–2015
- Section
- Battery › Checking specific gravity
Checking specific gravity
Note
- The following specific gravity test should only be performed on batteries without condition indicator.

Warning When using sulphuric acid it is absolutely necessary to adhere to the accident prevention procedures.
Suitable protective clothing must be worn.
Only use a torch to illuminate the inside of the battery housing.
Never illuminate the inside of a battery housing with an open flame.
Never work with an open flame or burning cigarette in the vicinity of a battery.
Ensure the legislation for the disposal of batteries and sulphuric acid is observed when disposing batteries.
The electrolyte temperature must be at least 10 °C.
The specific gravity must be checked in all battery cells as follows:
Switch off ignition.
Remove all battery plugs (battery cell sealing plugs).
Immerse end of hydrometer in a cell and extract sufficient electrolyte so that float swims free in the electrolyte.

The denser the extracted electrolyte the higher the float swims.
The density in kg/dm3 can be read off the scale of the hydrometer (specific density of electrolyte).
Read off measured value on hydrometer and compare with table:
| Charge condition in normal climatic zones | Specific densities in kg/dm3 |
|---|---|
| Discharged | 1.15 |
| Half charged | 1.22 |
| Well charged | 1.28 |
The electrolyte density must be at least 1.24kg/dm3.
Charge battery if electrolyte density (specific gravity) is insufficient.
Repeat electrolyte density (specific gravity) check after charging battery.
The measured value for the specific gravity of the individual battery cells must not differentiate in more than 0.03 kg/dm3.
| Battery cell: | 1 | 2 | 3 | 4 | 5 | 6 |
| Electrolyte density per cell in kg/dm3 | ||||||
| Example 1: | 1.24 | 1.25 | 1.25 | 1.10 | 1.24 | 1.25 |
| Example 2: | 1.26 | 1.26 | 1.25 | 1.14 | 1.18 | 1.24 |
Example 1:
The specific gravity in cell 4 is too low.
Example 2:
The specific gravity in cells 4 and 5 is too low. The electrolyte density deviations between the battery cells is more than 0.03 kg/dm3.
If the specifications are not obtained, renew battery.
If the specifications are obtained, screw plugs in again.
It is absolutely necessary to use original sealing plugs in the battery screwed openings to guarantee the battery is sealed correctly.
Use original sealing plugs of same construction if lost or damaged.
The sealing plugs must be fitted with an O-ring.